Change history for item: Gas Thermona THERM 28 KDZ 5

  1. Donny Darko 08 July 2023 11:05:42
    1. Create: Description #3452133
      Value: Type of heating boiler: gas, max. heating power: 26.40 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3452134
      Value: Gas, condensing
    3. Create: Burner #3452135
      Value: Gas
    4. Create: Number of circuits #3452136
      Value: Double-circuit
    5. Create: Thermal power #3452137
      Value: 4.90 - 26.40 kW
    6. Create: Thermal load #3452138
      Value: 6.60 - 28 kW
    7. Create: The combustion chamber #3452139
      Value: Closed
    8. Create: Efficiency #3452140
      Value: 106 %
    9. Create: Control #3452141
      Value: Electronic
    10. Create: Installation #3452142
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3452143
      Value: Stainless steel
    12. Create: Mains voltage #3452144
      Value: Single-phase
    13. Create: Peculiarities #3452145
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3452146
      Value: 5.5 l
    15. Create: Expansion tank volume #3452147
      Value: 7 l
    16. Create: Equipment #3452148
      Value: Built-in boiler, display
    17. Create: Fuel #3452149
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3452150
      Value: 2.85 cu. m/hour
    19. Create: LPG consumption #3452151
      Value: 0.93 kg/h
    20. Create: Nominal pressure of natural gas #3452152
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3452153
      Value: 37 mbar
    22. Create: Heat carrier temperature #3452154
      Value: 30 - 80 °С
    23. Create: Max. temperature in the DHW circuit #3452155
      Value: 60 °С
    24. Create: Hot water capacity at t 30°C #3452156
      Value: 16.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3452157
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3452158
      Value: 3 bar
    27. Create: Gas connection #3452159
      Value: 1/2"
    28. Create: Heating circuit connection #3452160
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3452161
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3452162
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3452163
      Value: 800x800x425mm
    32. Create: Weight #3452164
      Value: 67 kg