Change history for item: Gas Thermona THERM 28 TLXZ 10

  1. Donny Darko 08 July 2023 11:05:09
    1. Create: Description #3451901
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3451902
      Value: Gas, convection
    3. Create: Burner #3451903
      Value: Gas
    4. Create: Number of circuits #3451904
      Value: Double-circuit
    5. Create: Thermal power #3451905
      Value: 13 - 28 kW
    6. Create: The combustion chamber #3451906
      Value: Closed
    7. Create: Heated area #3451907
      Value: 280 sq.m
    8. Create: Efficiency #3451908
      Value: 90 %
    9. Create: Control #3451909
      Value: Electronic
    10. Create: Installation #3451910
      Value: Wall-mounted
    11. Create: Mains voltage #3451911
      Value: Single-phase
    12. Create: Peculiarities #3451912
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3451913
      Value: 100 l
    14. Create: Expansion tank volume #3451914
      Value: 10 l
    15. Create: Equipment #3451915
      Value: Built-in boiler, display
    16. Create: Fuel #3451916
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3451917
      Value: 3.25 cu. m/hour
    18. Create: LPG consumption #3451918
      Value: 1.2 kg/hour
    19. Create: Max. coolant temperature #3451919
      Value: 80 °C
    20. Create: Max. temperature in the DHW circuit #3451920
      Value: 65 °С
    21. Create: Max. water pressure in the DHW circuit #3451921
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3451922
      Value: 3 bar
    23. Create: Gas connection #3451923
      Value: 3/4"
    24. Create: Heating circuit connection #3451924
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3451925
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3451926
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3451927
      Value: 500x1635x535mm
    28. Create: Weight #3451928
      Value: 95 kg
    29. Create: Image #6331870
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id508493509011234413.jpeg/orig
    30. Create: Preview image #6331871
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id508493509011234413.jpeg/orig
  2. Donny Darko 30 April 2023 08:37:31
    Name: Gas Thermona THERM 28 TLXZ 10; Catalog: Heating boilers