Change history for item: Gas Thermona THERM 23 TCLN

  1. Donny Darko 08 July 2023 11:04:37
    1. Create: Description #3451748
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3451749
      Value: Gas, convection
    3. Create: Burner #3451750
      Value: Gas
    4. Create: Number of circuits #3451751
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3451752
      Value: 11 - 23 kW
    6. Create: Thermal load #3451753
      Value: 12.10 - 25.20 kW
    7. Create: The combustion chamber #3451754
      Value: Closed
    8. Create: Efficiency #3451755
      Value: 90 %
    9. Create: Control #3451756
      Value: Electronic
    10. Create: Installation #3451757
      Value: Wall-mounted
    11. Create: Mains voltage #3451758
      Value: Single-phase
    12. Create: Peculiarities #3451759
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3451760
      Value: 8 l
    14. Create: Equipment #3451761
      Value: Display
    15. Create: Fuel #3451762
      Value: Natural gas
    16. Create: Natural gas consumption #3451763
      Value: 2.65 cu. m/hour
    17. Create: Nominal pressure of natural gas #3451764
      Value: 20 mbar
    18. Create: Heat carrier temperature #3451765
      Value: 35 - 80 °С
    19. Create: Temperature in the DHW circuit #3451766
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3451767
      Value: 11.5 l/min
    21. Create: Hot water capacity at t 35°C #3451768
      Value: 8.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3451769
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3451770
      Value: 3 bar
    24. Create: Gas connection #3451771
      Value: 3/4"
    25. Create: Heating circuit connection #3451772
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3451773
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3451774
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3451775
      Value: 430x830x367 mm
    29. Create: Weight #3451776
      Value: 41 kg
    30. Create: Image #6331858
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5894630473636896781/orig
    31. Create: Preview image #6331859
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5894630473636896781/orig
  2. Donny Darko 30 April 2023 08:37:30
    Name: Gas Thermona THERM 23 TCLN; Catalog: Heating boilers