Change history for item: Gas Thermona THERM PRO 14 KX.A 55L

  1. Donny Darko 08 July 2023 11:04:01
    1. Create: Description #3451549
      Value: Type of heating boiler: gas, max. thermal power: 14 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3451550
      Value: Gas
    3. Create: Burner #3451551
      Value: Gas
    4. Create: Number of circuits #3451552
      Value: Double-circuit
    5. Create: Thermal power #3451553
      Value: 5 - 14 kW
    6. Create: Max. thermal load #3451554
      Value: 15.25 kW
    7. Create: The combustion chamber #3451555
      Value: Open
    8. Create: Efficiency #3451556
      Value: 92 %
    9. Create: Control #3451557
      Value: Electronic
    10. Create: Installation #3451558
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3451559
      Value: Copper
    12. Create: Secondary heat exchanger material #3451560
      Value: Stainless steel
    13. Create: Mains voltage #3451561
      Value: Single-phase
    14. Create: Peculiarities #3451562
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: The volume of the built-in boiler #3451563
      Value: 5.5 l
    16. Create: Expansion tank volume #3451564
      Value: 7 l
    17. Create: Equipment #3451565
      Value: Built-in boiler, display
    18. Create: Fuel #3451566
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3451567
      Value: 1.62 cu. m/hour
    20. Create: LPG consumption #3451568
      Value: 0.59 kg/h
    21. Create: Nominal pressure of natural gas #3451569
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3451570
      Value: 37 mbar
    23. Create: Max. coolant temperature #3451571
      Value: 80 °C
    24. Create: Max. temperature in the DHW circuit #3451572
      Value: 65 °С
    25. Create: Hot water capacity at t 30°C #3451573
      Value: 5 l/min
    26. Create: Max. water pressure in the DHW circuit #3451574
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3451575
      Value: 3 bar
    28. Create: Gas connection #3451576
      Value: 3/4"
    29. Create: Heating circuit connection #3451577
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3451578
      Value: 1/2"
    31. Create: Chimney diameter #3451579
      Value: 110 mm
    32. Create: Dimensions WxHxD #3451580
      Value: 630x830x435mm
    33. Create: Weight #3451581
      Value: 70 kg
    34. Create: Image #6331842
      URL: https://avatars.mds.yandex.net/get-mpic/2016828/img_id8446928660094469176/orig
    35. Create: Preview image #6331843
      URL: https://avatars.mds.yandex.net/get-mpic/2016828/img_id8446928660094469176/orig
  2. Donny Darko 30 April 2023 08:37:28
    Name: Gas Thermona THERM PRO 14 KX.A 55L; Catalog: Heating boilers