Change history for item: Gas Kiturami World Alpha 20 23.3 kW double-circuit

  1. Donny Darko 08 July 2023 10:56:33
    1. Create: Description #3449924
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3449925
      Value: Gas, convection
    3. Create: Burner #3449926
      Value: Gas
    4. Create: Number of circuits #3449927
      Value: Double-circuit
    5. Create: Thermal power #3449928
      Value: 9.30 - 23.30 kW
    6. Create: The combustion chamber #3449929
      Value: Closed
    7. Create: Heated area #3449930
      Value: 230 sq.m
    8. Create: Efficiency #3449931
      Value: 91.8 %
    9. Create: Control #3449932
      Value: Electronic
    10. Create: Installation #3449933
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3449934
      Value: Aluminum
    12. Create: Secondary heat exchanger material #3449935
      Value: Stainless steel
    13. Create: Mains voltage #3449936
      Value: Single-phase
    14. Create: Peculiarities #3449937
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
    15. Create: Expansion tank volume #3449938
      Value: 65 l
    16. Create: Equipment #3449939
      Value: Built-in exhaust fan, display, room thermostat, remote control
    17. Create: Fuel #3449940
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3449941
      Value: 22.8 cu. m/hour
    19. Create: LPG consumption #3449942
      Value: 1.71 kg/h
    20. Create: Nominal pressure of natural gas #3449943
      Value: 9.80 - 24.50 mbar
    21. Create: Permissible LPG pressure #3449944
      Value: 31.38 mbar
    22. Create: Heat carrier temperature #3449945
      Value: 45 - 85 °С
    23. Create: Temperature in the DHW circuit #3449946
      Value: 35 - 60 °С
    24. Create: Hot water capacity at t 25°C #3449947
      Value: 13.3 l/min
    25. Create: Hot water capacity at t 30°C #3449948
      Value: 11.1 l/min
    26. Create: Max. water pressure in the DHW circuit #3449949
      Value: 10 bar
    27. Create: Max. water pressure in the heating circuit #3449950
      Value: 3 bar
    28. Create: Gas connection #3449951
      Value: 3/4"
    29. Create: Heating circuit connection #3449952
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3449953
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3449954
      Value: 60/100 mm
    32. Create: Dimensions WxHxD #3449955
      Value: 440x680x220 mm
    33. Create: Weight #3449956
      Value: 24 kg
    34. Create: Additional Information #3449957
      Value: Seismic sensor
    35. Create: Image #6331579
      URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id5855005633101645092.png/orig
    36. Create: Image #6331580
      URL: https://avatars.mds.yandex.net/get-mpic/7052428/img_id2791607278841237281.png/orig
    37. Create: Preview image #6331581
      URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id5855005633101645092.png/orig
  2. Donny Darko 30 April 2023 08:36:59
    Name: Gas Kiturami World Alpha 20 23.3 kW double-circuit; Catalog: Heating boilers