Change history for item: Gas Kiturami World Alpha 16 18.6 kW double-circuit

  1. Donny Darko 08 July 2023 10:55:54
    1. Create: Description #3449674
      Value: Type of heating boiler: gas, max. heating power: 18.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3449675
      Value: Gas, convection
    3. Create: Burner #3449676
      Value: Gas
    4. Create: Number of circuits #3449677
      Value: Double-circuit
    5. Create: Thermal power #3449678
      Value: 7.40 - 18.60 kW
    6. Create: The combustion chamber #3449679
      Value: Closed
    7. Create: Heated area #3449680
      Value: 190 sq.m
    8. Create: Efficiency #3449681
      Value: 92.4 %
    9. Create: Control #3449682
      Value: Electronic
    10. Create: Installation #3449683
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3449684
      Value: Aluminum
    12. Create: Secondary heat exchanger material #3449685
      Value: Stainless steel
    13. Create: Mains voltage #3449686
      Value: Single-phase
    14. Create: Peculiarities #3449687
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
    15. Create: Expansion tank volume #3449688
      Value: 65 l
    16. Create: Equipment #3449689
      Value: Built-in exhaust fan, display, room thermostat, remote control
    17. Create: Fuel #3449690
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3449691
      Value: 1.82 cu. m/hour
    19. Create: LPG consumption #3449692
      Value: 1.33 kg/h
    20. Create: Nominal pressure of natural gas #3449693
      Value: 9.80 - 24.50 mbar
    21. Create: Permissible LPG pressure #3449694
      Value: 31.38 mbar
    22. Create: Heat carrier temperature #3449695
      Value: 45 - 85 °С
    23. Create: Temperature in the DHW circuit #3449696
      Value: 35 - 60 °С
    24. Create: Hot water capacity at t 25°C #3449697
      Value: 10.7 l/min
    25. Create: Hot water capacity at t 30°C #3449698
      Value: 8.9 l/min
    26. Create: Hot water capacity at t 35°C #3449699
      Value: 6.7 l/min
    27. Create: Max. water pressure in the DHW circuit #3449700
      Value: 10 bar
    28. Create: Max. water pressure in the heating circuit #3449701
      Value: 3 bar
    29. Create: Gas connection #3449702
      Value: 3/4"
    30. Create: Heating circuit connection #3449703
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3449704
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3449705
      Value: 60/100 mm
    33. Create: Dimensions WxHxD #3449706
      Value: 440x680x220 mm
    34. Create: Weight #3449707
      Value: 24 kg
    35. Create: Additional Information #3449708
      Value: Seismic sensor
    36. Create: Image #6331548
      URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id3468752350945149886.png/orig
    37. Create: Image #6331549
      URL: https://avatars.mds.yandex.net/get-mpic/5169675/img_id5871989490713118301.jpeg/orig
    38. Create: Preview image #6331550
      URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id3468752350945149886.png/orig
  2. Donny Darko 30 April 2023 08:36:55
    Name: Gas Kiturami World Alpha 16 18.6 kW double-circuit; Catalog: Heating boilers