Change history for item: Gas Kiturami World 5000 25R 29.1 kW double-circuit

  1. Donny Darko 08 July 2023 10:53:40
    1. Create: Description #3448838
      Value: Type of heating boiler: gas, max. heating power: 29.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3448839
      Value: Gas, convection
    3. Create: Burner #3448840
      Value: Gas
    4. Create: Number of circuits #3448841
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3448842
      Value: 10.50 - 29.10 kW
    6. Create: Thermal load #3448843
      Value: 12.20 - 34.60 kW
    7. Create: The combustion chamber #3448844
      Value: Closed
    8. Create: Efficiency #3448845
      Value: 91.8 %
    9. Create: Control #3448846
      Value: Electronic
    10. Create: Installation #3448847
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3448848
      Value: Stainless steel
    12. Create: Mains voltage #3448849
      Value: Single-phase
    13. Create: Peculiarities #3448850
      Value: Built-in expansion tank, built-in circulation pump, thermometer
    14. Create: Expansion tank volume #3448851
      Value: 7 l
    15. Create: Equipment #3448852
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3448853
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3448854
      Value: 2.98 cu. m/hour
    18. Create: LPG consumption #3448855
      Value: 2.48 kg/hour
    19. Create: Heat carrier temperature #3448856
      Value: 45 - 85 °С
    20. Create: Temperature in the DHW circuit #3448857
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3448858
      Value: 16.7 l/min
    22. Create: Hot water capacity at t 40°C #3448859
      Value: 10.4 l/min
    23. Create: Max. water pressure in the DHW circuit #3448860
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3448861
      Value: 3 bar
    25. Create: Gas connection #3448862
      Value: 1/2"
    26. Create: Heating circuit connection #3448863
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3448864
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3448865
      Value: 75/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3448866
      Value: Yes
    30. Create: Dimensions WxHxD #3448867
      Value: 486x730x210 mm
    31. Create: Weight #3448868
      Value: 29 kg
    32. Create: Image #6331391
      URL: https://avatars.mds.yandex.net/get-mpic/1750349/img_id1390821505464832968/orig
    33. Create: Preview image #6331392
      URL: https://avatars.mds.yandex.net/get-mpic/1750349/img_id1390821505464832968/orig