Change history for item: Gas Kiturami World 5000 20R 23.2 kW double-circuit

  1. Donny Darko 08 July 2023 10:53:36
    1. Create: Description #3448807
      Value: Type of heating boiler: gas, max. thermal power: 23.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3448808
      Value: Gas, convection
    3. Create: Burner #3448809
      Value: Gas
    4. Create: Number of circuits #3448810
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3448811
      Value: 10.40 - 23.20 kW
    6. Create: Thermal load #3448812
      Value: 12.80 - 27.70 kW
    7. Create: The combustion chamber #3448813
      Value: Closed
    8. Create: Efficiency #3448814
      Value: 92.3 %
    9. Create: Control #3448815
      Value: Electronic
    10. Create: Installation #3448816
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3448817
      Value: Stainless steel
    12. Create: Mains voltage #3448818
      Value: Single-phase
    13. Create: Peculiarities #3448819
      Value: Built-in expansion tank, built-in circulation pump, thermometer
    14. Create: Expansion tank volume #3448820
      Value: 7 l
    15. Create: Equipment #3448821
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3448822
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3448823
      Value: 2.38 cu. m/hour
    18. Create: LPG consumption #3448824
      Value: 1.98 kg/hour
    19. Create: Heat carrier temperature #3448825
      Value: 45 - 85 °С
    20. Create: Temperature in the DHW circuit #3448826
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3448827
      Value: 13.3 l/min
    22. Create: Hot water capacity at t 40°C #3448828
      Value: 8.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3448829
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3448830
      Value: 3 bar
    25. Create: Gas connection #3448831
      Value: 1/2"
    26. Create: Heating circuit connection #3448832
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3448833
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3448834
      Value: 75/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3448835
      Value: Yes
    30. Create: Dimensions WxHxD #3448836
      Value: 486x730x210 mm
    31. Create: Weight #3448837
      Value: 28 kg
    32. Create: Image #6331389
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id2215641716206604699/orig
    33. Create: Preview image #6331390
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id2215641716206604699/orig
  2. Donny Darko 30 April 2023 08:36:46
    Name: Gas Kiturami World 5000 20R 23.2 kW double-circuit; Catalog: Heating boilers