Change history for item: Gas boiler Immergas Hercules Solar 26 23.6 kW double-circuit

  1. Donny Darko 08 July 2023 10:48:26
    1. Create: Description #3447620
      Value: Type of heating boiler: gas, max. heating power: 23.60 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3447621
      Value: Gas, condensing
    3. Create: Burner #3447622
      Value: Gas
    4. Create: Number of circuits #3447623
      Value: Double-circuit
    5. Create: Thermal power #3447624
      Value: 3 - 23.60 kW
    6. Create: Thermal load #3447625
      Value: 3.20 - 24.30 kW
    7. Create: The combustion chamber #3447626
      Value: Closed
    8. Create: Efficiency #3447627
      Value: 107.5 %
    9. Create: Control #3447628
      Value: Electronic
    10. Create: Installation #3447629
      Value: Floor
    11. Create: Secondary heat exchanger material #3447630
      Value: Stainless steel
    12. Create: Mains voltage #3447631
      Value: Single-phase
    13. Create: Peculiarities #3447632
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3447633
      Value: 200 l
    15. Create: Expansion tank volume #3447634
      Value: 10.8 l
    16. Create: Equipment #3447635
      Value: Built-in boiler, display
    17. Create: Fuel #3447636
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3447637
      Value: 2.85 cu. m/hour
    19. Create: LPG consumption #3447638
      Value: 2.13 kg/hour
    20. Create: Nominal pressure of natural gas #3447639
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3447640
      Value: 37 mbar
    22. Create: Heat carrier temperature #3447641
      Value: 25 - 85 °С
    23. Create: Temperature in the DHW circuit #3447642
      Value: 20 - 60 °C
    24. Create: Hot water capacity at t 30°C #3447643
      Value: 13.1 l/min
    25. Create: Max. water pressure in the DHW circuit #3447644
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3447645
      Value: 3 bar
    27. Create: Gas connection #3447646
      Value: 1/2"
    28. Create: Heating circuit connection #3447647
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3447648
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3447649
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3447650
      Value: Yes
    32. Create: Dimensions WxHxD #3447651
      Value: 600x1970x750mm
    33. Create: Weight #3447652
      Value: 193.8 kg
    34. Create: Image #6331233
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id8951017924185698895.jpeg/orig
    35. Create: Preview image #6331234
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id8951017924185698895.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:28
    Name: Gas boiler Immergas Hercules Solar 26 23.6 kW double-circuit; Catalog: Heating boilers