    1. Create: Description #3447450
      Value: Type of heating boiler: gas, max. heating power: 20.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3447451
      Value: Gas, condensing
    3. Create: Burner #3447452
      Value: Gas
    4. Create: Number of circuits #3447453
      Value: Double-circuit
    5. Create: Thermal power #3447454
      Value: 3 - 20.50 kW
    6. Create: Thermal load #3447455
      Value: 3.10 - 21.30 kW
    7. Create: The combustion chamber #3447456
      Value: Closed
    8. Create: Efficiency #3447457
      Value: 104.6 %
    9. Create: Control #3447458
      Value: Electronic
    10. Create: Installation #3447459
      Value: Wall-mounted
    11. Create: Mains voltage #3447460
      Value: Single-phase
    12. Create: Peculiarities #3447461
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3447462
      Value: 5.8 l
    14. Create: Equipment #3447463
      Value: Display
    15. Create: Fuel #3447464
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3447465
      Value: 2.61 cu. m/hour
    17. Create: LPG consumption #3447466
      Value: 1.91 kg/hour
    18. Create: Nominal pressure of natural gas #3447467
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3447468
      Value: 37 mbar
    20. Create: Heat carrier temperature #3447469
      Value: 20 - 85 °С
    21. Create: Temperature in the DHW circuit #3447470
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 30°C #3447471
      Value: 12.2 l/min
    23. Create: Max. water pressure in the DHW circuit #3447472
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3447473
      Value: 3 bar
    25. Create: Gas connection #3447474
      Value: 3/4"
    26. Create: Heating circuit connection #3447475
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3447476
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3447477
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3447478
      Value: Yes
    30. Create: Dimensions WxHxD #3447479
      Value: 440x748x280mm
    31. Create: Weight #3447480
      Value: 32 kg