Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:47:49
Create:
Description #3447388
Value: Type of heating boiler: gas, max. heating power: 31.70 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3447389
Value: Gas, convection
Create:
Burner #3447390
Value: Gas
Create:
Number of circuits #3447391
Value: Double-circuit
Create:
Thermal power #3447392
Value: 12.50 - 31.70 kW
Create:
Thermal load #3447393
Value: 14.20 - 33.60 kW
Create:
The combustion chamber #3447394
Value: Closed
Create:
Efficiency #3447395
Value: 94.3 %
Create:
Control #3447396
Value: Electronic
Create:
Installation #3447397
Value: Floor
Create:
Secondary heat exchanger material #3447398
Value: Stainless steel
Create:
Mains voltage #3447399
Value: Single-phase
Create:
Peculiarities #3447400
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3447401
Value: 120 l
Create:
Expansion tank volume #3447402
Value: 10.8 l
Create:
Equipment #3447403
Value: Built-in boiler, display
Create:
Fuel #3447404
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3447405
Value: 3.62 cu. m/hour
Create:
LPG consumption #3447406
Value: 2.67 kg/h
Create:
Nominal pressure of natural gas #3447407
Value: 20 mbar
Create:
Permissible LPG pressure #3447408
Value: 37 mbar
Create:
Heat carrier temperature #3447409
Value: 35 - 85 °С
Create:
Temperature in the DHW circuit #3447410
Value: 20 - 60 °C
Create:
Hot water capacity at t 30°C #3447411
Value: 24.9 l/min
Create:
Max. water pressure in the DHW circuit #3447412
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3447413
Value: 3 bar
Create:
Gas connection #3447414
Value: 1/2"
Create:
Heating circuit connection #3447415
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3447416
Value: 3/4"
Create:
Coaxial chimney diameter #3447417
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3447418
Value: Yes
Create:
Dimensions WxHxD #3447419
Value: 600x1600x600 mm
Create:
Weight #3447420
Value: 125.5 kg
Create:
Additional Information #3447421
Value: DHW expansion tank; DHW circulation pump
Create:
Image #6331217
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2945933375426837984/orig
Create:
Preview image #6331218
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2945933375426837984/orig
Donny Darko 30 April 2023 08:36:26
Name: Gas boiler Immergas Hercules 32 kW 120I 31.7 kW double-circuit; Catalog: Heating boilers