Change history for item: Gas boiler Immergas Hercules Condensing 32 kW

  1. Donny Darko 08 July 2023 10:47:14
    1. Create: Description #3447156
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3447157
      Value: Gas, condensing
    3. Create: Burner #3447158
      Value: Gas
    4. Create: Number of circuits #3447159
      Value: Double-circuit
    5. Create: Thermal power #3447160
      Value: 6.90 - 32 kW
    6. Create: Thermal load #3447161
      Value: 7.30 - 33 kW
    7. Create: The combustion chamber #3447162
      Value: Closed
    8. Create: Efficiency #3447163
      Value: 107.3 %
    9. Create: Control #3447164
      Value: Electronic
    10. Create: Installation #3447165
      Value: Floor
    11. Create: Secondary heat exchanger material #3447166
      Value: Stainless steel
    12. Create: Mains voltage #3447167
      Value: Single-phase
    13. Create: Peculiarities #3447168
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3447169
      Value: 120 l
    15. Create: Expansion tank volume #3447170
      Value: 10.8 l
    16. Create: Equipment #3447171
      Value: Built-in boiler, display
    17. Create: Fuel #3447172
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3447173
      Value: 3.49 cu. m/hour
    19. Create: LPG consumption #3447174
      Value: 2.61 kg/hour
    20. Create: Nominal pressure of natural gas #3447175
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3447176
      Value: 37 mbar
    22. Create: Heat carrier temperature #3447177
      Value: 25 - 85 °С
    23. Create: Temperature in the DHW circuit #3447178
      Value: 20 - 60 °C
    24. Create: Hot water capacity at t 30°C #3447179
      Value: 16 l/min
    25. Create: Max. water pressure in the DHW circuit #3447180
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3447181
      Value: 3 bar
    27. Create: Gas connection #3447182
      Value: 1/2"
    28. Create: Heating circuit connection #3447183
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3447184
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3447185
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3447186
      Value: Yes
    32. Create: Dimensions WxHxD #3447187
      Value: 600x1600x600 mm
    33. Create: Weight #3447188
      Value: 112 kg
    34. Create: Image #6331201
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id1524891325164866418.jpeg/orig
    35. Create: Preview image #6331202
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id1524891325164866418.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:24
    Name: Gas boiler Immergas Hercules Condensing 32 kW; Catalog: Heating boilers