Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:46:41
Create:
Description #3446917
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3446918
Value: Gas, convection
Create:
Burner #3446919
Value: Gas
Create:
Number of circuits #3446920
Value: Double-circuit
Create:
Thermal power #3446921
Value: 11 - 28 kW
Create:
Thermal load #3446922
Value: 12.60 - 29.80 kW
Create:
The combustion chamber #3446923
Value: Closed
Create:
Efficiency #3446924
Value: 93.1 %
Create:
Control #3446925
Value: Electronic
Create:
Installation #3446926
Value: Wall-mounted
Create:
Secondary heat exchanger material #3446927
Value: Stainless steel
Create:
Mains voltage #3446928
Value: Single-phase
Create:
Peculiarities #3446929
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
Create:
The volume of the built-in boiler #3446930
Value: 4.5 l
Create:
Expansion tank volume #3446931
Value: 10 l
Create:
Equipment #3446932
Value: Built-in boiler
Create:
Fuel #3446933
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3446934
Value: 3.16 cu. m/hour
Create:
LPG consumption #3446935
Value: 2.35 kg/hour
Create:
Nominal pressure of natural gas #3446936
Value: 20 mbar
Create:
Permissible LPG pressure #3446937
Value: 37 mbar
Create:
Heat carrier temperature #3446938
Value: 35 - 90 °С
Create:
Temperature in the DHW circuit #3446939
Value: 20 - 60 °C
Create:
Hot water capacity at t 30°C #3446940
Value: 13.4 l/min
Create:
Max. water pressure in the DHW circuit #3446941
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3446942
Value: 3 bar
Create:
Gas connection #3446943
Value: 3/4"
Create:
Heating circuit connection #3446944
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3446945
Value: 1/2"
Create:
Coaxial chimney diameter #3446946
Value: 60/100 mm and 80/125 mm
Create:
Dimensions WxHxD #3446947
Value: 580x890x380 mm
Create:
Weight #3446948
Value: 58 kg
Create:
Image #6331185
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id549995642986810203/orig
Create:
Preview image #6331186
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id549995642986810203/orig
Donny Darko 30 April 2023 08:36:22
Name: Gas boiler Immergas Zeus 28 kW 28 kW double-circuit; Catalog: Heating boilers