Change history for item: Gas boiler Immergas Major Eolo 28 4

  1. Donny Darko 08 July 2023 10:45:19
    1. Create: Description #3446491
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3446492
      Value: Gas, convection
    3. Create: Burner #3446493
      Value: Gas
    4. Create: Number of circuits #3446494
      Value: Double-circuit
    5. Create: Thermal power #3446495
      Value: 11.20 - 28 kW
    6. Create: Thermal load #3446496
      Value: 12.70 - 29.70 kW
    7. Create: The combustion chamber #3446497
      Value: Closed
    8. Create: Efficiency #3446498
      Value: 94.3 %
    9. Create: Control #3446499
      Value: Electronic
    10. Create: Installation #3446500
      Value: Wall-mounted
    11. Create: Mains voltage #3446501
      Value: Single-phase
    12. Create: Peculiarities #3446502
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3446503
      Value: 6.8 l
    14. Create: Equipment #3446504
      Value: Display
    15. Create: Fuel #3446505
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446506
      Value: 3.14 cu. m/hour
    17. Create: LPG consumption #3446507
      Value: 2.35 kg/hour
    18. Create: Nominal pressure of natural gas #3446508
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3446509
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446510
      Value: 35 - 90 °С
    21. Create: Temperature in the DHW circuit #3446511
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 30°C #3446512
      Value: 13.7 l/min
    23. Create: Max. water pressure in the DHW circuit #3446513
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3446514
      Value: 3 bar
    25. Create: Gas connection #3446515
      Value: 3/4"
    26. Create: Heating circuit connection #3446516
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3446517
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3446518
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3446519
      Value: Yes
    30. Create: Dimensions WxHxD #3446520
      Value: 440x781x340mm
    31. Create: Image #6331150
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id754458628880733579/orig
    32. Create: Preview image #6331151
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id754458628880733579/orig
  2. Donny Darko 30 April 2023 08:36:18
    Name: Gas boiler Immergas Major Eolo 28 4; Catalog: Heating boilers