Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:45:03
Create:
Description #3446397
Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3446398
Value: Gas, convection
Create:
Burner #3446399
Value: Gas
Create:
Number of circuits #3446400
Value: Double-circuit
Create:
Thermal power #3446401
Value: 9.10 - 23.70 kW
Create:
Thermal load #3446402
Value: 10.50 - 25.60 kW
Create:
The combustion chamber #3446403
Value: Closed
Create:
Efficiency #3446404
Value: 93.2 %
Create:
Control #3446405
Value: Electronic
Create:
Installation #3446406
Value: Wall-mounted
Create:
Mains voltage #3446407
Value: Single-phase
Create:
Peculiarities #3446408
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3446409
Value: 8 l
Create:
Equipment #3446410
Value: Display
Create:
Fuel #3446411
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3446412
Value: 2.71 cu. m/hour
Create:
LPG consumption #3446413
Value: 2.01 kg/h
Create:
Nominal pressure of natural gas #3446414
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3446415
Value: 37 mbar
Create:
Heat carrier temperature #3446416
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3446417
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3446418
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3446419
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3446420
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3446421
Value: 3 bar
Create:
Gas connection #3446422
Value: 3/4"
Create:
Heating circuit connection #3446423
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3446424
Value: 1/2"
Create:
Coaxial chimney diameter #3446425
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3446426
Value: Yes
Create:
Dimensions WxHxD #3446427
Value: 400x820x350 mm
Create:
Weight #3446428
Value: 37 kg
Create:
Image #6331144
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id1161783721552928125/orig
Create:
Preview image #6331145
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id1161783721552928125/orig
Donny Darko 30 April 2023 08:36:16
Name: Hermann THESI 24SE 23.7 kW dual circuit; Catalog: Heating boilers