      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3446336
      Value: Gas, convection
    3. Create: Burner #3446337
      Value: Gas
    4. Create: Number of circuits #3446338
      Value: Double-circuit
    5. Create: Thermal power #3446339
      Value: 9.10 - 23.10 kW
    6. Create: Thermal load #3446340
      Value: 10.50 - 25.60 kW
    7. Create: The combustion chamber #3446341
      Value: Open
    8. Create: Efficiency #3446342
      Value: 90.8 %
    9. Create: Control #3446343
      Value: Electronic
    10. Create: Installation #3446344
      Value: Wall-mounted
    11. Create: Mains voltage #3446345
      Value: Single-phase
    12. Create: Peculiarities #3446346
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3446347
      Value: 8 l
    14. Create: Equipment #3446348
      Value: Display
    15. Create: Fuel #3446349
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446350
      Value: 2.71 cu. m/hour
    17. Create: LPG consumption #3446351
      Value: 2.01 kg/h
    18. Create: Nominal pressure of natural gas #3446352
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3446353
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446354
      Value: 30 - 80 °С
    21. Create: Temperature in the DHW circuit #3446355
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3446356
      Value: 13.2 l/min
    23. Create: Hot water capacity at t 30°C #3446357
      Value: 11 l/min
    24. Create: Max. water pressure in the DHW circuit #3446358
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3446359
      Value: 3 bar
    26. Create: Gas connection #3446360
      Value: 3/4"
    27. Create: Heating circuit connection #3446361
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3446362
      Value: 1/2"
    29. Create: Chimney diameter #3446363
      Value: 130 mm
    30. Create: Dimensions WxHxD #3446364
      Value: 400x820x350 mm
    31. Create: Weight #3446365
      Value: 33 kg