Change history for item: Hermann Supermaster INox 23E 23.1 kW dual circuit

  1. Donny Darko 08 July 2023 10:44:50
    1. Create: Description #3446303
      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3446304
      Value: Gas, convection
    3. Create: Burner #3446305
      Value: Gas
    4. Create: Number of circuits #3446306
      Value: Double-circuit
    5. Create: Thermal power #3446307
      Value: 9.10 - 23.10 kW
    6. Create: Thermal load #3446308
      Value: 10.50 - 25.60 kW
    7. Create: The combustion chamber #3446309
      Value: Open
    8. Create: Efficiency #3446310
      Value: 90.8 %
    9. Create: Control #3446311
      Value: Electronic
    10. Create: Installation #3446312
      Value: Wall-mounted
    11. Create: Mains voltage #3446313
      Value: Single-phase
    12. Create: Peculiarities #3446314
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: The volume of the built-in boiler #3446315
      Value: 60 l
    14. Create: Expansion tank volume #3446316
      Value: 12 l
    15. Create: Equipment #3446317
      Value: Built-in boiler
    16. Create: Fuel #3446318
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3446319
      Value: 2.71 cu. m/hour
    18. Create: LPG consumption #3446320
      Value: 2.01 kg/h
    19. Create: Nominal pressure of natural gas #3446321
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3446322
      Value: 37 mbar
    21. Create: Heat carrier temperature #3446323
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3446324
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 25°C #3446325
      Value: 13.2 l/min
    24. Create: Hot water capacity at t 30°C #3446326
      Value: 11 l/min
    25. Create: Max. water pressure in the DHW circuit #3446327
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3446328
      Value: 3 bar
    27. Create: Gas connection #3446329
      Value: 3/4"
    28. Create: Heating circuit connection #3446330
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3446331
      Value: 1/2"
    30. Create: Chimney diameter #3446332
      Value: 130 mm
    31. Create: Dimensions WxHxD #3446333
      Value: 600x900x438mm
    32. Create: Weight #3446334
      Value: 76 kg
    33. Create: Image #6331138
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id9094105597030643060.jpeg/orig
    34. Create: Preview image #6331139
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id9094105597030643060.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:16
    Name: Hermann Supermaster INox 23E 23.1 kW dual circuit; Catalog: Heating boilers