Heating boilers
Donny Darko 08 July 2023 10:44:43
Create:
Description #3446271
Value: Type of heating boiler: gas, max. heating power: 27.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3446272
Value: Gas, convection
Create:
Burner #3446273
Value: Gas
Create:
Number of circuits #3446274
Value: Double-circuit
Create:
Thermal power #3446275
Value: 11.40 - 27.50 kW
Create:
Thermal load #3446276
Value: 13.20 - 30.50 kW
Create:
The combustion chamber #3446277
Value: Open
Create:
Efficiency #3446278
Value: 91.4 %
Create:
Control #3446279
Value: Electronic
Create:
Installation #3446280
Value: Wall-mounted
Create:
Mains voltage #3446281
Value: Single-phase
Create:
Peculiarities #3446282
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3446283
Value: 60 l
Create:
Expansion tank volume #3446284
Value: 12 l
Create:
Equipment #3446285
Value: Built-in boiler
Create:
Fuel #3446286
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3446287
Value: 3.22 cu. m/hour
Create:
LPG consumption #3446288
Value: 2.36 kg/h
Create:
Nominal pressure of natural gas #3446289
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3446290
Value: 37 mbar
Create:
Heat carrier temperature #3446291
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3446292
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3446293
Value: 15.8 l/min
Create:
Hot water capacity at t 30°C #3446294
Value: 13.2 l/min
Create:
Max. water pressure in the DHW circuit #3446295
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3446296
Value: 3 bar
Create:
Gas connection #3446297
Value: 3/4"
Create:
Heating circuit connection #3446298
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3446299
Value: 1/2"
Create:
Chimney diameter #3446300
Value: 140 mm
Create:
Dimensions WxHxD #3446301
Value: 600x900x438mm
Create:
Weight #3446302
Value: 79 kg
Create:
Image #6331136
URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id4465601013049332445.jpeg/orig
Create:
Preview image #6331137
URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id4465601013049332445.jpeg/orig
Donny Darko 30 April 2023 08:36:15