Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:44:37
Create:
Description #3446238
Value: Type of heating boiler: gas, max. heating power: 29.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3446239
Value: Gas, convection
Create:
Burner #3446240
Value: Gas
Create:
Number of circuits #3446241
Value: Double-circuit
Create:
Thermal power #3446242
Value: 11 - 29.50 kW
Create:
Thermal load #3446243
Value: 13.20 - 32.70 kW
Create:
The combustion chamber #3446244
Value: Closed
Create:
Efficiency #3446245
Value: 93.4 %
Create:
Control #3446246
Value: Electronic
Create:
Installation #3446247
Value: Wall-mounted
Create:
Mains voltage #3446248
Value: Single-phase
Create:
Peculiarities #3446249
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3446250
Value: 60 l
Create:
Expansion tank volume #3446251
Value: 12 l
Create:
Equipment #3446252
Value: Built-in boiler
Create:
Fuel #3446253
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3446254
Value: 3.46 cu. m/hour
Create:
LPG consumption #3446255
Value: 2.53 kg/hour
Create:
Nominal pressure of natural gas #3446256
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3446257
Value: 37 mbar
Create:
Heat carrier temperature #3446258
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3446259
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3446260
Value: 16.9 l/min
Create:
Hot water capacity at t 30°C #3446261
Value: 14.1 l/min
Create:
Max. water pressure in the DHW circuit #3446262
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3446263
Value: 3 bar
Create:
Gas connection #3446264
Value: 3/4"
Create:
Heating circuit connection #3446265
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3446266
Value: 1/2"
Create:
Coaxial chimney diameter #3446267
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3446268
Value: Yes
Create:
Dimensions WxHxD #3446269
Value: 600x900x438mm
Create:
Weight #3446270
Value: 83 kg
Create:
Image #6331134
URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id3871261653868908050.jpeg/orig
Create:
Preview image #6331135
URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id3871261653868908050.jpeg/orig
Donny Darko 30 April 2023 08:36:15
Name: Hermann Supermaster INox 30SE 29.5 kW dual circuit; Catalog: Heating boilers