Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:44:31
Create:
Description #3446205
Value: Type of heating boiler: gas, max. heating power: 23.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3446206
Value: Gas, convection
Create:
Burner #3446207
Value: Gas
Create:
Number of circuits #3446208
Value: Double-circuit
Create:
Thermal power #3446209
Value: 8.90 - 23.60 kW
Create:
Thermal load #3446210
Value: 10.50 - 25.60 kW
Create:
The combustion chamber #3446211
Value: Closed
Create:
Efficiency #3446212
Value: 92.1 %
Create:
Control #3446213
Value: Electronic
Create:
Installation #3446214
Value: Wall-mounted
Create:
Mains voltage #3446215
Value: Single-phase
Create:
Peculiarities #3446216
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3446217
Value: 60 l
Create:
Expansion tank volume #3446218
Value: 12 l
Create:
Equipment #3446219
Value: Built-in boiler
Create:
Fuel #3446220
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3446221
Value: 2.71 cu. m/hour
Create:
LPG consumption #3446222
Value: 2.01 kg/h
Create:
Nominal pressure of natural gas #3446223
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3446224
Value: 37 mbar
Create:
Heat carrier temperature #3446225
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3446226
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3446227
Value: 13.5 l/min
Create:
Hot water capacity at t 30°C #3446228
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3446229
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3446230
Value: 3 bar
Create:
Gas connection #3446231
Value: 3/4"
Create:
Heating circuit connection #3446232
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3446233
Value: 1/2"
Create:
Coaxial chimney diameter #3446234
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3446235
Value: Yes
Create:
Dimensions WxHxD #3446236
Value: 600x900x438mm
Create:
Weight #3446237
Value: 80 kg
Create:
Image #6331132
URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id5804342488805324352.jpeg/orig
Create:
Preview image #6331133
URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id5804342488805324352.jpeg/orig
Donny Darko 30 April 2023 08:36:15
Name: Hermann Supermaster INox 24SE 23.6 kW dual circuit; Catalog: Heating boilers