Change history for item: Hermann EURA Top Condensing 26 27.3 kW double circuit

  1. Donny Darko 08 July 2023 10:44:23
    1. Create: Description #3446143
      Value: Type of heating boiler: gas, max. heating power: 27.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3446144
      Value: Gas, condensing
    3. Create: Burner #3446145
      Value: Gas
    4. Create: Number of circuits #3446146
      Value: Double-circuit
    5. Create: Thermal power #3446147
      Value: 5.20 - 27.30 kW
    6. Create: Thermal load #3446148
      Value: 5.40 - 26 kW
    7. Create: The combustion chamber #3446149
      Value: Closed
    8. Create: Efficiency #3446150
      Value: 105.1 %
    9. Create: Control #3446151
      Value: Electronic
    10. Create: Installation #3446152
      Value: Wall-mounted
    11. Create: Mains voltage #3446153
      Value: Single-phase
    12. Create: Peculiarities #3446154
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3446155
      Value: 8 l
    14. Create: Equipment #3446156
      Value: Display
    15. Create: Fuel #3446157
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446158
      Value: 2.75 cu. m/hour
    17. Create: LPG consumption #3446159
      Value: 2.02 kg/hour
    18. Create: Nominal pressure of natural gas #3446160
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3446161
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446162
      Value: 20 - 80 °C
    21. Create: Temperature in the DHW circuit #3446163
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3446164
      Value: 14.5 l/min
    23. Create: Hot water capacity at t 30°C #3446165
      Value: 12 l/min
    24. Create: Max. water pressure in the DHW circuit #3446166
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3446167
      Value: 3 bar
    26. Create: Gas connection #3446168
      Value: 3/4"
    27. Create: Heating circuit connection #3446169
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3446170
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3446171
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3446172
      Value: 450x833x377 mm
    31. Create: Weight #3446173
      Value: 47 kg
    32. Create: Image #6331128
      URL: https://avatars.mds.yandex.net/get-mpic/4591438/img_id6384297590999688587.jpeg/orig
    33. Create: Preview image #6331129
      URL: https://avatars.mds.yandex.net/get-mpic/4591438/img_id6384297590999688587.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:14
    Name: Hermann EURA Top Condensing 26 27.3 kW double circuit; Catalog: Heating boilers