Change history for item: Hermann MICRA2 30SE

  1. Donny Darko 08 July 2023 10:44:18
    1. Create: Description #3446111
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3446112
      Value: Gas, convection
    3. Create: Burner #3446113
      Value: Gas
    4. Create: Number of circuits #3446114
      Value: Double-circuit
    5. Create: Thermal power #3446115
      Value: 11.40 - 30 kW
    6. Create: Thermal load #3446116
      Value: 13.20 - 32 kW
    7. Create: The combustion chamber #3446117
      Value: Closed
    8. Create: Efficiency #3446118
      Value: 93.7 %
    9. Create: Control #3446119
      Value: Electronic
    10. Create: Installation #3446120
      Value: Wall-mounted
    11. Create: Mains voltage #3446121
      Value: Single-phase
    12. Create: Peculiarities #3446122
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3446123
      Value: 8 l
    14. Create: Equipment #3446124
      Value: Display
    15. Create: Fuel #3446125
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446126
      Value: 3.38 cu. m/hour
    17. Create: LPG consumption #3446127
      Value: 2.52 kg/h
    18. Create: Nominal pressure of natural gas #3446128
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3446129
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446130
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3446131
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3446132
      Value: 17.2 l/min
    23. Create: Hot water capacity at t 30°C #3446133
      Value: 14.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3446134
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3446135
      Value: 3 bar
    26. Create: Gas connection #3446136
      Value: 3/4"
    27. Create: Heating circuit connection #3446137
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3446138
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3446139
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3446140
      Value: Yes
    31. Create: Dimensions WxHxD #3446141
      Value: 400x700x300mm
    32. Create: Weight #3446142
      Value: 37 kg
    33. Create: Image #6331126
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id1051873908477764076.jpeg/orig
    34. Create: Preview image #6331127
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id1051873908477764076.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:14
    Name: Hermann MICRA2 30SE; Catalog: Heating boilers