Change history for item: Hermann Habitat2 23E 23.2 kW dual circuit

  1. Donny Darko 08 July 2023 10:44:05
    1. Create: Description #3446017
      Value: Type of heating boiler: gas, max. heating power: 23.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3446018
      Value: Gas, convection
    3. Create: Burner #3446019
      Value: Gas
    4. Create: Number of circuits #3446020
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3446021
      Value: 8.60 - 23.20 kW
    6. Create: Thermal load #3446022
      Value: 10 - 25.60 kW
    7. Create: The combustion chamber #3446023
      Value: Open
    8. Create: Efficiency #3446024
      Value: 90.4 %
    9. Create: Control #3446025
      Value: Electronic
    10. Create: Installation #3446026
      Value: Wall-mounted
    11. Create: Mains voltage #3446027
      Value: Single-phase
    12. Create: Peculiarities #3446028
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3446029
      Value: 8 l
    14. Create: Equipment #3446030
      Value: Display
    15. Create: Fuel #3446031
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446032
      Value: 2.71 cu. m/hour
    17. Create: LPG consumption #3446033
      Value: 2.01 kg/h
    18. Create: Nominal pressure of natural gas #3446034
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3446035
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446036
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3446037
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3446038
      Value: 13.3 l/min
    23. Create: Hot water capacity at t 30°C #3446039
      Value: 11.1 l/min
    24. Create: Max. water pressure in the DHW circuit #3446040
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3446041
      Value: 3 bar
    26. Create: Gas connection #3446042
      Value: 3/4"
    27. Create: Heating circuit connection #3446043
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3446044
      Value: 1/2"
    29. Create: Chimney diameter #3446045
      Value: 130 mm
    30. Create: Dimensions WxHxD #3446046
      Value: 400x700x300mm
    31. Create: Weight #3446047
      Value: 29 kg
    32. Create: Image #6331120
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7899092867534214664.jpeg/orig
    33. Create: Preview image #6331121
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7899092867534214664.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:13
    Name: Hermann Habitat2 23E 23.2 kW dual circuit; Catalog: Heating boilers