Change history for item: Hermann Habitat2 24SE 23.7 kW dual circuit

  1. Donny Darko 08 July 2023 10:44:02
    1. Create: Description #3445985
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3445986
      Value: Gas, convection
    3. Create: Burner #3445987
      Value: Gas
    4. Create: Number of circuits #3445988
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3445989
      Value: 8.60 - 23.70 kW
    6. Create: Thermal load #3445990
      Value: 10 - 25.60 kW
    7. Create: The combustion chamber #3445991
      Value: Closed
    8. Create: Efficiency #3445992
      Value: 93.4 %
    9. Create: Control #3445993
      Value: Electronic
    10. Create: Installation #3445994
      Value: Wall-mounted
    11. Create: Mains voltage #3445995
      Value: Single-phase
    12. Create: Peculiarities #3445996
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3445997
      Value: 8 l
    14. Create: Equipment #3445998
      Value: Display
    15. Create: Fuel #3445999
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3446000
      Value: 2.71 cu. m/hour
    17. Create: LPG consumption #3446001
      Value: 2.01 kg/h
    18. Create: Nominal pressure of natural gas #3446002
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3446003
      Value: 37 mbar
    20. Create: Heat carrier temperature #3446004
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3446005
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3446006
      Value: 13.6 l/min
    23. Create: Hot water capacity at t 30°C #3446007
      Value: 11.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3446008
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3446009
      Value: 3 bar
    26. Create: Gas connection #3446010
      Value: 3/4"
    27. Create: Heating circuit connection #3446011
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3446012
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3446013
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3446014
      Value: Yes
    31. Create: Dimensions WxHxD #3446015
      Value: 400x700x300mm
    32. Create: Weight #3446016
      Value: 34.5 kg
    33. Create: Image #6331118
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id305320134736937170.jpeg/orig
    34. Create: Preview image #6331119
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id305320134736937170.jpeg/orig
  2. Donny Darko 30 April 2023 08:36:13
    Name: Hermann Habitat2 24SE 23.7 kW dual circuit; Catalog: Heating boilers