Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:43:58
Create:
Description #3445953
Value: Type of heating boiler: gas, max. thermal power: 27.60 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3445954
Value: Gas, convection
Create:
Burner #3445955
Value: Gas
Create:
Number of circuits #3445956
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3445957
Value: 9.50 - 27.60 kW
Create:
Thermal load #3445958
Value: 11 - 27.60 kW
Create:
The combustion chamber #3445959
Value: Closed
Create:
Efficiency #3445960
Value: 92.9 %
Create:
Control #3445961
Value: Electronic
Create:
Installation #3445962
Value: Wall-mounted
Create:
Mains voltage #3445963
Value: Single-phase
Create:
Peculiarities #3445964
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3445965
Value: 8 l
Create:
Equipment #3445966
Value: Display
Create:
Fuel #3445967
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3445968
Value: 3.14 cu. m/hour
Create:
LPG consumption #3445969
Value: 2.34 kg/h
Create:
Nominal pressure of natural gas #3445970
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3445971
Value: 37 mbar
Create:
Heat carrier temperature #3445972
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3445973
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3445974
Value: 15.8 l/min
Create:
Hot water capacity at t 30°C #3445975
Value: 13.2 l/min
Create:
Max. water pressure in the DHW circuit #3445976
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3445977
Value: 3 bar
Create:
Gas connection #3445978
Value: 3/4"
Create:
Heating circuit connection #3445979
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3445980
Value: 1/2"
Create:
Coaxial chimney diameter #3445981
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3445982
Value: Yes
Create:
Dimensions WxHxD #3445983
Value: 400x700x300mm
Create:
Weight #3445984
Value: 34.5 kg
Create:
Image #6331116
URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id311584381018036052.jpeg/orig
Create:
Preview image #6331117
URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id311584381018036052.jpeg/orig
Donny Darko 30 April 2023 08:36:13
Name: Hermann Habitat2 28SE 27.6 kW dual circuit; Catalog: Heating boilers