Change history for item: Chaffoteaux Pigma 30 FF 30 kW dual circuit

  1. Donny Darko 08 July 2023 10:40:41
    1. Create: Description #3444988
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3444989
      Value: Gas, convection
    3. Create: Burner #3444990
      Value: Gas
    4. Create: Number of circuits #3444991
      Value: Double-circuit
    5. Create: Thermal power #3444992
      Value: 13 - 30 kW
    6. Create: Thermal load #3444993
      Value: 14.40 - 33.30 kW
    7. Create: The combustion chamber #3444994
      Value: Closed
    8. Create: Efficiency #3444995
      Value: 93.9 %
    9. Create: Control #3444996
      Value: Electronic
    10. Create: Installation #3444997
      Value: Wall-mounted
    11. Create: Secondary heat exchanger material #3444998
      Value: Stainless steel
    12. Create: Mains voltage #3444999
      Value: Single-phase
    13. Create: Peculiarities #3445000
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3445001
      Value: 8 l
    15. Create: Equipment #3445002
      Value: Display
    16. Create: Fuel #3445003
      Value: Natural gas, liquefied gas
    17. Create: Nominal pressure of natural gas #3445004
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3445005
      Value: 37 mbar
    19. Create: Heat carrier temperature #3445006
      Value: 35 - 85 °С
    20. Create: Temperature in the DHW circuit #3445007
      Value: 36 - 60 °С
    21. Create: Hot water capacity at t 25°C #3445008
      Value: 16.9 l/min
    22. Create: Hot water capacity at t 30°C #3445009
      Value: 14.1 l/min
    23. Create: Hot water capacity at t 35°C #3445010
      Value: 12.1 l/min
    24. Create: Max. water pressure in the DHW circuit #3445011
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3445012
      Value: 3 bar
    26. Create: Gas connection #3445013
      Value: 3/4"
    27. Create: Heating circuit connection #3445014
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3445015
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3445016
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3445017
      Value: Yes
    31. Create: Dimensions WxHxD #3445018
      Value: 400x770x319 mm
    32. Create: Weight #3445019
      Value: 30 kg
    33. Create: Image #6330998
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id3439774078154031582/orig
    34. Create: Preview image #6330999
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id3439774078154031582/orig
  2. Donny Darko 30 April 2023 08:35:58
    Name: Chaffoteaux Pigma 30 FF 30 kW dual circuit; Catalog: Heating boilers