Change history for item: Chaffoteaux Alixia S 24 FF 25.8 kW dual circuit

  1. Donny Darko 08 July 2023 10:39:31
    1. Create: Description #3444495
      Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3444496
      Value: Gas, convection
    3. Create: Burner #3444497
      Value: Gas
    4. Create: Number of circuits #3444498
      Value: Double-circuit
    5. Create: Thermal power #3444499
      Value: 11.20 - 25.80 kW
    6. Create: The combustion chamber #3444500
      Value: Closed
    7. Create: Efficiency #3444501
      Value: 93.8 %
    8. Create: Control #3444502
      Value: Electronic
    9. Create: Installation #3444503
      Value: Wall-mounted
    10. Create: Mains voltage #3444504
      Value: Single-phase
    11. Create: Peculiarities #3444505
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    12. Create: Expansion tank volume #3444506
      Value: 8 l
    13. Create: Fuel #3444507
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3444508
      Value: 2.73 cu. m/hour
    15. Create: LPG consumption #3444509
      Value: 2.03 kg/h
    16. Create: Nominal pressure of natural gas #3444510
      Value: 20 mbar
    17. Create: Permissible LPG pressure #3444511
      Value: 37 mbar
    18. Create: Heat carrier temperature #3444512
      Value: 35 - 85 °С
    19. Create: Temperature in the DHW circuit #3444513
      Value: 36 - 60 °С
    20. Create: Hot water capacity at t 25°C #3444514
      Value: 13.9 l/min
    21. Create: Hot water capacity at t 30°C #3444515
      Value: 11.6 l/min
    22. Create: Hot water capacity at t 35°C #3444516
      Value: 9.9 l/min
    23. Create: Max. water pressure in the DHW circuit #3444517
      Value: 7 bar
    24. Create: Max. water pressure in the heating circuit #3444518
      Value: 3 bar
    25. Create: Gas connection #3444519
      Value: 3/4"
    26. Create: Heating circuit connection #3444520
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3444521
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3444522
      Value: 60/100 mm and 80/125 mm
    29. Create: Dimensions WxHxD #3444523
      Value: 400x745x319 mm
    30. Create: Weight #3444524
      Value: 30 kg
    31. Create: Image #6330964
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id815683986134223841.jpeg/orig
    32. Create: Preview image #6330965
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id815683986134223841.jpeg/orig
  2. Donny Darko 30 April 2023 08:35:54
    Name: Chaffoteaux Alixia S 24 FF 25.8 kW dual circuit; Catalog: Heating boilers