Change history for item: Gas boiler BaltGaz NEVA 21 Turbo

  1. Donny Darko 08 July 2023 10:37:47
    1. Create: Description #3443850
      Value: Type of heating boiler: gas, max. thermal power: 21 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3443851
      Value: Gas, convection
    3. Create: Burner #3443852
      Value: Gas
    4. Create: Number of circuits #3443853
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3443854
      Value: 8.90 - 21 kW
    6. Create: Max. thermal load #3443855
      Value: 22.80 kW
    7. Create: The combustion chamber #3443856
      Value: Closed
    8. Create: Heated area #3443857
      Value: 210 sq.m
    9. Create: Efficiency #3443858
      Value: 92 %
    10. Create: Control #3443859
      Value: Electronic
    11. Create: Installation #3443860
      Value: Wall-mounted
    12. Create: Mains voltage #3443861
      Value: Single-phase
    13. Create: Peculiarities #3443862
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, gas filter
    14. Create: Expansion tank volume #3443863
      Value: 6 l
    15. Create: Equipment #3443864
      Value: Display
    16. Create: Fuel #3443865
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3443866
      Value: 2.4 cu. m/hour
    18. Create: LPG consumption #3443867
      Value: 1.8 kg/hour
    19. Create: Nominal pressure of natural gas #3443868
      Value: 6 - 20 mbar
    20. Create: Permissible LPG pressure #3443869
      Value: 29 mbar
    21. Create: Heat carrier temperature #3443870
      Value: 20 - 80 °C
    22. Create: Temperature in the DHW circuit #3443871
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3443872
      Value: 13.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3443873
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3443874
      Value: 3 bar
    26. Create: Gas connection #3443875
      Value: 3/4"
    27. Create: Heating circuit connection #3443876
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3443877
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3443878
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3443879
      Value: Yes
    31. Create: Dimensions WxHxD #3443880
      Value: 420x700x270 mm
    32. Create: Weight #3443881
      Value: 28.5 kg
    33. Create: Image #6330898
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3640171568171052164/orig
    34. Create: Preview image #6330899
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3640171568171052164/orig
  2. Donny Darko 30 April 2023 08:35:48
    Name: Gas boiler BaltGaz NEVA 21 Turbo; Catalog: Heating boilers