Change history for item: Convection gas boiler BaltGaz Turbo E 24, 24 kW, double-circuit

  1. Donny Darko 08 July 2023 10:37:32
    1. Create: Description #3443788
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3443789
      Value: Gas, convection
    3. Create: Burner #3443790
      Value: Gas
    4. Create: Number of circuits #3443791
      Value: Double-circuit
    5. Create: Thermal power #3443792
      Value: 9 - 24 kW
    6. Create: The combustion chamber #3443793
      Value: Closed
    7. Create: Heated area #3443794
      Value: 240 sq.m
    8. Create: Efficiency #3443795
      Value: 92 %
    9. Create: Control #3443796
      Value: Electronic
    10. Create: Installation #3443797
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3443798
      Value: Copper
    12. Create: Mains voltage #3443799
      Value: Single-phase
    13. Create: Peculiarities #3443800
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer, water filter
    14. Create: Expansion tank volume #3443801
      Value: 6 l
    15. Create: Equipment #3443802
      Value: Display
    16. Create: Recommended fuel #3443803
      Value: Natural gas
    17. Create: Fuel #3443804
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3443805
      Value: 2.8 cu. m/hour
    19. Create: LPG consumption #3443806
      Value: 2 kg/hour
    20. Create: Heat carrier temperature #3443807
      Value: 30 - 80 °С
    21. Create: Temperature in the DHW circuit #3443808
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3443809
      Value: 13.4 l/min
    23. Create: Max. water pressure in the DHW circuit #3443810
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3443811
      Value: 3 bar
    25. Create: Gas connection #3443812
      Value: 3/4"
    26. Create: Heating circuit connection #3443813
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3443814
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3443815
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3443816
      Value: Yes
    30. Create: Dimensions WxHxD #3443817
      Value: 420x700x270 mm
    31. Create: Image #6330887
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id2187158225119600010.jpeg/orig
    32. Create: Image #6330888
      URL: https://avatars.mds.yandex.net/get-mpic/4516625/img_id6268852731382611830.jpeg/orig
    33. Create: Image #6330889
      URL: https://avatars.mds.yandex.net/get-mpic/4413406/img_id324617151514636006.jpeg/orig
    34. Create: Image #6330890
      URL: https://avatars.mds.yandex.net/get-mpic/5236119/img_id7688542300090849278.jpeg/orig
    35. Create: Image #6330891
      URL: https://avatars.mds.yandex.net/get-mpic/5235397/img_id6355302429684920547.jpeg/orig
    36. Create: Image #6330892
      URL: https://avatars.mds.yandex.net/get-mpic/4012265/img_id7147087703395266801.jpeg/orig
    37. Create: Image #6330893
      URL: https://avatars.mds.yandex.net/get-mpic/1600461/img_id8534675595410719871.jpeg/orig
    38. Create: Image #6330894
      URL: https://avatars.mds.yandex.net/get-mpic/6069273/img_id778113519155153878.jpeg/orig
    39. Create: Preview image #6330895
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id2187158225119600010.jpeg/orig
  2. Donny Darko 30 April 2023 08:35:47
    Name: Convection gas boiler BaltGaz Turbo E 24, 24 kW, double-circuit; Catalog: Heating boilers