Change history for item: Gas boiler NEVALUX 7224 24 kW double-circuit with a closed chamber

  1. Donny Darko 08 July 2023 10:37:20
    1. Create: Width #33072
      Value: 370
    2. Create: Height #33073
      Value: 67
    3. Create: Description #3443716
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    4. Create: Type of heating boiler #3443717
      Value: Gas
    5. Create: Number of circuits #3443718
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3443719
      Value: Convection
    7. Create: The principle of operation of a solid fuel boiler #3443720
      Value: A gas boiler
    8. Create: Combustion chamber type #3443721
      Value: Closed
    9. Create: Primary heat exchanger material #3443722
      Value: Copper
    10. Create: Accommodation #3443723
      Value: Wall
    11. Create: Non-volatile #3443724
      Value: There is
    12. Create: Control #3443725
      Value: Mechanical
    13. Create: Functions #3443726
      Value: Auto diagnostics
    14. Create: Max. thermal power #3443727
      Value: 24 kW
    15. Create: Efficiency #3443728
      Value: 92 %
    16. Create: Heated area #3443729
      Value: 240 m²
    17. Create: Minimum heating medium temperature #3443730
      Value: 25°C
    18. Create: Maximum coolant temperature #3443731
      Value: 80°C
    19. Create: Expansion tank volume #3443732
      Value: 6 l
    20. Create: Gas connection #3443733
      Value: 3/4"
    21. Create: Heating circuit connection #3443734
      Value: 3/4"
    22. Create: Branch pipe for connecting the DHW circuit #3443735
      Value: 1/2"
    23. Create: Coaxial chimney diameter #3443736
      Value: 60/100 mm
    24. Create: Burner #3443737
      Value: Gas
    25. Create: Bithermic heat exchanger #3443738
      Value: There is
    26. Create: Minimum temperature in the DHW circuit #3443739
      Value: 30°C
    27. Create: Maximum temperature in the DHW circuit #3443740
      Value: 60°C
    28. Create: Fuel #3443741
      Value: Natural gas
    29. Create: Hot water capacity at t 25°C #3443742
      Value: 13.5 l/min
    30. Create: Natural gas consumption #3443743
      Value: 2.8 m³/hour
    31. Create: Depth #3443744
      Value: 25 mm
    32. Create: Weight #3443745
      Value: 27 kg
    33. Create: Image #6330876
      URL: https://avatars.mds.yandex.net/get-mpic/5258494/img_id5807546287125656174.jpeg/orig
    34. Create: Image #6330877
      URL: https://avatars.mds.yandex.net/get-mpic/5236535/img_id4869319918432310797.jpeg/orig
    35. Create: Image #6330878
      URL: https://avatars.mds.yandex.net/get-mpic/5347553/img_id9102968477401960853.jpeg/orig
    36. Create: Image #6330879
      URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id532795246731692696.jpeg/orig
    37. Create: Image #6330880
      URL: https://avatars.mds.yandex.net/get-mpic/1591646/img_id655922162075084373.jpeg/orig
    38. Create: Image #6330881
      URL: https://avatars.mds.yandex.net/get-mpic/1581127/img_id8377540393683668003.jpeg/orig
    39. Create: Preview image #6330882
      URL: https://avatars.mds.yandex.net/get-mpic/5258494/img_id5807546287125656174.jpeg/orig
  2. Donny Darko 30 April 2023 08:35:47
    Name: Gas boiler NEVALUX 7224 24 kW double-circuit with a closed chamber; Catalog: Heating boilers