Change history for item: Gas boiler BaltGaz Turbo S 10

  1. Donny Darko 08 July 2023 10:36:11
    1. Create: Description #3443409
      Value: Type of heating boiler: gas, max. thermal power: 10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3443410
      Value: Gas, convection
    3. Create: Burner #3443411
      Value: Gas
    4. Create: Number of circuits #3443412
      Value: Double-circuit
    5. Create: Thermal power #3443413
      Value: 8.50 - 10 kW
    6. Create: Max. thermal load #3443414
      Value: 10.90 kW
    7. Create: The combustion chamber #3443415
      Value: Closed
    8. Create: Heated area #3443416
      Value: 100 sq.m
    9. Create: Efficiency #3443417
      Value: 90 %
    10. Create: Control #3443418
      Value: Electronic
    11. Create: Installation #3443419
      Value: Wall-mounted
    12. Create: Mains voltage #3443420
      Value: Single-phase
    13. Create: Peculiarities #3443421
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3443422
      Value: 6 l
    15. Create: Equipment #3443423
      Value: Display
    16. Create: Fuel #3443424
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3443425
      Value: 1.1 cu. m/hour
    18. Create: LPG consumption #3443426
      Value: 0.9 kg/hour
    19. Create: Nominal pressure of natural gas #3443427
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3443428
      Value: 29 mbar
    21. Create: Heat carrier temperature #3443429
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3443430
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3443431
      Value: 11 l/min
    24. Create: Max. water pressure in the DHW circuit #3443432
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3443433
      Value: 3 bar
    26. Create: Gas connection #3443434
      Value: 3/4"
    27. Create: Heating circuit connection #3443435
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3443436
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3443437
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3443438
      Value: Yes
    31. Create: Dimensions WxHxD #3443439
      Value: 420x700x270 mm
    32. Create: Weight #3443440
      Value: 28.5 kg
    33. Create: Image #6330823
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id7166887209719874235.jpeg/orig
    34. Create: Preview image #6330824
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id7166887209719874235.jpeg/orig
  2. Donny Darko 30 April 2023 08:35:41
    Name: Gas boiler BaltGaz Turbo S 10; Catalog: Heating boilers