Change history for item: Gas Leberg Flamme 12 ASF

  1. Donny Darko 08 July 2023 10:14:58
    1. Create: Description #3438372
      Value: Type of heating boiler: gas, max. heating power: 10.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3438373
      Value: Gas, convection
    3. Create: Burner #3438374
      Value: Gas
    4. Create: Number of circuits #3438375
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3438376
      Value: 3.30 - 10.90 kW
    6. Create: Max. thermal load #3438377
      Value: 12 kW
    7. Create: The combustion chamber #3438378
      Value: Closed
    8. Create: Efficiency #3438379
      Value: 91 %
    9. Create: Control #3438380
      Value: Electronic
    10. Create: Installation #3438381
      Value: Wall-mounted
    11. Create: Mains voltage #3438382
      Value: Single-phase
    12. Create: Peculiarities #3438383
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3438384
      Value: 6 l
    14. Create: Equipment #3438385
      Value: Display
    15. Create: Fuel #3438386
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3438387
      Value: 1.19 cu. m/hour
    17. Create: Nominal pressure of natural gas #3438388
      Value: 20 mbar
    18. Create: Heat carrier temperature #3438389
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3438390
      Value: 35 - 65 °С
    20. Create: Hot water capacity at t 25°C #3438391
      Value: 6.8 l/min
    21. Create: Hot water capacity at t 30°C #3438392
      Value: 5 l/min
    22. Create: Max. water pressure in the DHW circuit #3438393
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3438394
      Value: 3 bar
    24. Create: Gas connection #3438395
      Value: 3/4"
    25. Create: Heating circuit connection #3438396
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3438397
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3438398
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3438399
      Value: 410x740x315 mm
    29. Create: Weight #3438400
      Value: 33.8 kg
    30. Create: Image #6330190
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id6241332548888443387/orig
    31. Create: Preview image #6330191
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id6241332548888443387/orig
  2. Donny Darko 30 April 2023 08:34:24
    Name: Gas Leberg Flamme 12 ASF; Catalog: Heating boilers