Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:12:28
Create:
Description #3437560
Value: Type of heating boiler: gas, max. thermal power: 40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3437561
Value: Gas, convection
Create:
Burner #3437562
Value: Gas
Create:
Number of circuits #3437563
Value: Double-circuit
Create:
Thermal power #3437564
Value: 10.20 - 40 kW
Create:
Thermal load #3437565
Value: 11.80 - 44 kW
Create:
The combustion chamber #3437566
Value: Closed
Create:
Heated area #3437567
Value: 400 sq.m
Create:
Efficiency #3437568
Value: 91.1 %
Create:
Control #3437569
Value: Electronic
Create:
Installation #3437570
Value: Wall-mounted
Create:
Primary heat exchanger material #3437571
Value: Copper
Create:
Secondary heat exchanger material #3437572
Value: Stainless steel
Create:
Mains voltage #3437573
Value: Single-phase
Create:
Peculiarities #3437574
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3437575
Value: 7 l
Create:
Equipment #3437576
Value: Display, Boiler, manual, box., wall mounting bracket
Create:
Fuel for automatic feeding #3437577
Value: Gas
Create:
Fuel #3437578
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3437579
Value: 3.2 cu. m/hour
Create:
LPG consumption #3437580
Value: 4 kg/hour
Create:
Nominal pressure of natural gas #3437581
Value: 20 mbar
Create:
Permissible LPG pressure #3437582
Value: 28 mbar
Create:
Heat carrier temperature #3437583
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3437584
Value: 30 - 60 °С
Create:
Hot water capacity at t 25°C #3437585
Value: 29.1 l/min
Create:
Max. water pressure in the DHW circuit #3437586
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3437587
Value: 3 bar
Create:
Gas connection #3437588
Value: 3/4"
Create:
Heating circuit connection #3437589
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3437590
Value: 3/4"
Create:
Coaxial chimney diameter #3437591
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3437592
Value: Yes
Create:
Dimensions WxHxD #3437593
Value: 410x652x317 mm
Create:
Weight #3437594
Value: 29 kg
Create:
Image #6330115
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Create:
Image #6330116
URL: https://avatars.mds.yandex.net/get-mpic/4794619/img_id3856066376833238442.jpeg/orig
Create:
Image #6330117
URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id4135391739613202469.jpeg/orig
Create:
Image #6330118
URL: https://avatars.mds.yandex.net/get-mpic/1926093/img_id4254078399855697038.png/orig
Create:
Image #6330119
URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id8619109829126200131.jpeg/orig
Create:
Image #6330120
URL: https://avatars.mds.yandex.net/get-mpic/4345877/img_id1583504031469388314.jpeg/orig
Create:
Preview image #6330121
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Donny Darko 30 April 2023 08:34:14
Name: Gas Arderia D40 40 kW double-circuit; Catalog: Heating boilers