Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:12:21
Create:
Description #3437490
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3437491
Value: Gas, convection
Create:
Burner #3437492
Value: Gas
Create:
Number of circuits #3437493
Value: Double-circuit
Create:
Thermal power #3437494
Value: 5 - 28 kW
Create:
Thermal load #3437495
Value: 5.80 - 30 kW
Create:
The combustion chamber #3437496
Value: Closed
Create:
Heated area #3437497
Value: 280 sq.m
Create:
Efficiency #3437498
Value: 90 %
Create:
Control #3437499
Value: Electronic
Create:
Installation #3437500
Value: Wall-mounted
Create:
Primary heat exchanger material #3437501
Value: Copper
Create:
Secondary heat exchanger material #3437502
Value: Stainless steel
Create:
Mains voltage #3437503
Value: Single-phase
Create:
Peculiarities #3437504
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3437505
Value: 7 l
Create:
Equipment #3437506
Value: Display, Boiler, manual, box., wall mounting bracket
Create:
Fuel for automatic feeding #3437507
Value: Gas
Create:
Fuel #3437508
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3437509
Value: 2.2 cu. m/hour
Create:
LPG consumption #3437510
Value: 2.5 kg/hour
Create:
Nominal pressure of natural gas #3437511
Value: 20 mbar
Create:
Permissible LPG pressure #3437512
Value: 28 mbar
Create:
Heat carrier temperature #3437513
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3437514
Value: 30 - 60 °С
Create:
Hot water capacity at t 25°C #3437515
Value: 18.7 l/min
Create:
Max. water pressure in the DHW circuit #3437516
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3437517
Value: 3 bar
Create:
Gas connection #3437518
Value: 3/4"
Create:
Heating circuit connection #3437519
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3437520
Value: 3/4"
Create:
Coaxial chimney diameter #3437521
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3437522
Value: Yes
Create:
Dimensions WxHxD #3437523
Value: 410x652x317 mm
Create:
Weight #3437524
Value: 29 kg
Create:
Image #6330095
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Create:
Image #6330096
URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id5170064151564120099.jpeg/orig
Create:
Image #6330097
URL: https://avatars.mds.yandex.net/get-mpic/1886039/img_id8389523956911192365.jpeg/orig
Create:
Image #6330098
URL: https://avatars.mds.yandex.net/get-mpic/4794619/img_id3856066376833238442.jpeg/orig
Create:
Image #6330099
URL: https://avatars.mds.yandex.net/get-mpic/2991631/img_id5945231395999118778.jpeg/orig
Create:
Image #6330100
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id613790616728711137.jpeg/orig
Create:
Image #6330101
URL: https://avatars.mds.yandex.net/get-mpic/5255974/img_id2898368119092028962.jpeg/orig
Create:
Image #6330102
URL: https://avatars.mds.yandex.net/get-mpic/1943683/img_id4689736449502753189.jpeg/orig
Create:
Image #6330103
URL: https://avatars.mds.yandex.net/get-mpic/5326769/img_id7684023165034709884.jpeg/orig
Create:
Image #6330104
URL: https://avatars.mds.yandex.net/get-mpic/5277894/img_id8681665884390063756.jpeg/orig
Create:
Image #6330105
URL: https://avatars.mds.yandex.net/get-mpic/4345877/img_id1583504031469388314.jpeg/orig
Create:
Preview image #6330106
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Donny Darko 30 April 2023 08:34:13
Name: Gas Arderia D28 28 kW double-circuit; Catalog: Heating boilers