Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 10:11:57
Create:
Description #3437292
Value: Type of heating boiler: gas, max. thermal power: 40 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3437293
Value: Gas, convection
Create:
Burner #3437294
Value: Gas
Create:
Number of circuits #3437295
Value: Single-loop
Create:
Thermal power #3437296
Value: 10.20 - 40 kW
Create:
Thermal load #3437297
Value: 11.80 - 44 kW
Create:
The combustion chamber #3437298
Value: Closed
Create:
Heated area #3437299
Value: 400 sq.m
Create:
Efficiency #3437300
Value: 91.1 %
Create:
Control #3437301
Value: Electronic
Create:
Installation #3437302
Value: Wall-mounted
Create:
Primary heat exchanger material #3437303
Value: Copper
Create:
Mains voltage #3437304
Value: Single-phase
Create:
Peculiarities #3437305
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3437306
Value: 7 l
Create:
Equipment #3437307
Value: Display, Boiler, manual, box., wall mounting bracket
Create:
Fuel for automatic feeding #3437308
Value: Gas
Create:
Fuel #3437309
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3437310
Value: 3.2 cu. m/hour
Create:
LPG consumption #3437311
Value: 4 kg/hour
Create:
Nominal pressure of natural gas #3437312
Value: 20 mbar
Create:
Permissible LPG pressure #3437313
Value: 28 mbar
Create:
Heat carrier temperature #3437314
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3437315
Value: 30 - 60 °С
Create:
Max. water pressure in the DHW circuit #3437316
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3437317
Value: 3 bar
Create:
Gas connection #3437318
Value: 3/4"
Create:
Heating circuit connection #3437319
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3437320
Value: 3/4"
Create:
Coaxial chimney diameter #3437321
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3437322
Value: Yes
Create:
Dimensions WxHxD #3437323
Value: 410x652x317 mm
Create:
Weight #3437324
Value: 29 kg
Create:
Image #6330044
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Create:
Image #6330045
URL: https://avatars.mds.yandex.net/get-mpic/1060343/img_id2028714178352679344.png/orig
Create:
Image #6330046
URL: https://avatars.mds.yandex.net/get-mpic/5236045/img_id1853943930896716463.png/orig
Create:
Image #6330047
URL: https://avatars.mds.yandex.net/get-mpic/4466428/img_id7262400525446332336.jpeg/orig
Create:
Image #6330048
URL: https://avatars.mds.yandex.net/get-mpic/4794619/img_id3856066376833238442.jpeg/orig
Create:
Image #6330049
URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id8619109829126200131.jpeg/orig
Create:
Preview image #6330050
URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
Donny Darko 30 April 2023 08:34:12
Name: Gas Arderia S40 40 kW single circuit; Catalog: Heating boilers