Change history for item: Gas Arderia B32 32 kW double-circuit

  1. Donny Darko 08 July 2023 10:09:11
    1. Create: Description #3436213
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3436214
      Value: Gas, convection
    3. Create: Burner #3436215
      Value: Gas
    4. Create: Number of circuits #3436216
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3436217
      Value: 8.20 - 32 kW
    6. Create: Thermal load #3436218
      Value: 9.50 - 35 kW
    7. Create: The combustion chamber #3436219
      Value: Closed
    8. Create: Heated area #3436220
      Value: 320 sq.m
    9. Create: Efficiency #3436221
      Value: 91.4 %
    10. Create: Control #3436222
      Value: Electronic
    11. Create: Installation #3436223
      Value: Wall-mounted
    12. Create: Mains voltage #3436224
      Value: Single-phase
    13. Create: Peculiarities #3436225
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3436226
      Value: 65 l
    15. Create: Equipment #3436227
      Value: Display
    16. Create: Fuel #3436228
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3436229
      Value: 2.5 cu. m/hour
    18. Create: LPG consumption #3436230
      Value: 3 kg/hour
    19. Create: Nominal pressure of natural gas #3436231
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3436232
      Value: 28 mbar
    21. Create: Heat carrier temperature #3436233
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3436234
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3436235
      Value: 2.33 l/min
    24. Create: Max. water pressure in the DHW circuit #3436236
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3436237
      Value: 3 bar
    26. Create: Gas connection #3436238
      Value: 3/4"
    27. Create: Heating circuit connection #3436239
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3436240
      Value: 3/4"
    29. Create: Coaxial chimney diameter #3436241
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3436242
      Value: 420x652x318 mm
    31. Create: Image #6329863
      URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
    32. Create: Image #6329864
      URL: https://avatars.mds.yandex.net/get-mpic/5228682/img_id8956256409860419479.png/orig
    33. Create: Preview image #6329865
      URL: https://avatars.mds.yandex.net/get-mpic/4568822/img_id8167290978868853851.png/orig
  2. Donny Darko 30 April 2023 08:34:00
    Name: Gas Arderia B32 32 kW double-circuit; Catalog: Heating boilers