Change history for item: Gas boiler Oasis BM-16

  1. Donny Darko 08 July 2023 10:05:45
    1. Create: Description #3434852
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3434853
      Value: Gas, convection
    3. Create: Burner #3434854
      Value: Gas
    4. Create: Number of circuits #3434855
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Max. thermal power #3434856
      Value: 16 kW
    6. Create: The combustion chamber #3434857
      Value: Closed
    7. Create: Heated area #3434858
      Value: 160 sq.m
    8. Create: Control #3434859
      Value: Electronic
    9. Create: Installation #3434860
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3434861
      Value: Copper
    11. Create: Mains voltage #3434862
      Value: Single-phase
    12. Create: Peculiarities #3434863
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3434864
      Value: 6 l
    14. Create: Equipment #3434865
      Value: Display
    15. Create: Fuel #3434866
      Value: Natural gas, liquefied gas
    16. Create: Nominal pressure of natural gas #3434867
      Value: 13 - 20 mbar
    17. Create: Permissible LPG pressure #3434868
      Value: 37 mbar
    18. Create: Heat carrier temperature #3434869
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3434870
      Value: 36 - 60 °С
    20. Create: Hot water capacity at t 25°C #3434871
      Value: 8 l/min
    21. Create: Max. water pressure in the DHW circuit #3434872
      Value: 8 bar
    22. Create: Max. water pressure in the heating circuit #3434873
      Value: 3 bar
    23. Create: Gas connection #3434874
      Value: 3/4"
    24. Create: Heating circuit connection #3434875
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3434876
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3434877
      Value: 60/100 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3434878
      Value: Yes
    28. Create: Dimensions WxHxD #3434879
      Value: 420x740x310 mm
    29. Create: Weight #3434880
      Value: 33.4 kg
    30. Create: Image #6329591
      URL: https://avatars.mds.yandex.net/get-mpic/4219717/img_id4278371222471741985.jpeg/orig
    31. Create: Preview image #6329592
      URL: https://avatars.mds.yandex.net/get-mpic/4219717/img_id4278371222471741985.jpeg/orig
  2. Donny Darko 30 April 2023 08:33:44
    Name: Gas boiler Oasis BM-16; Catalog: Heating boilers