Change history for item: Gas TAGANROG GAS APPLIANCE KSGV-16P 16 kW double-circuit

  1. Donny Darko 08 July 2023 08:01:54
    1. Create: Description #3430584
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3430585
      Value: Gas, convection
    3. Create: Burner #3430586
      Value: Gas
    4. Create: Number of circuits #3430587
      Value: Double-circuit
    5. Create: Max. thermal power #3430588
      Value: 16 kW
    6. Create: Non-volatile #3430589
      Value: Yes
    7. Create: The combustion chamber #3430590
      Value: Closed
    8. Create: Heated area #3430591
      Value: 160 sq.m
    9. Create: Efficiency #3430592
      Value: 92 %
    10. Create: Control #3430593
      Value: Mechanical
    11. Create: Installation #3430594
      Value: Parapet
    12. Create: Primary heat exchanger material #3430595
      Value: Steel
    13. Create: Peculiarities #3430596
      Value: Thermometer
    14. Create: Fuel #3430597
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3430598
      Value: 1.5 cu. m/hour
    16. Create: LPG consumption #3430599
      Value: 11.2 kg/hour
    17. Create: Nominal pressure of natural gas #3430600
      Value: 6 - 28 mbar
    18. Create: Permissible LPG pressure #3430601
      Value: 29.4 mbar
    19. Create: Max. coolant temperature #3430602
      Value: 90 °С
    20. Create: Hot water capacity at t 20°C #3430603
      Value: 7.5 l/min
    21. Create: Hot water capacity at t 30°C #3430604
      Value: 4.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3430605
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3430606
      Value: 1 bar
    24. Create: Gas connection #3430607
      Value: 1/2"
    25. Create: Heating circuit connection #3430608
      Value: 1¼
    26. Create: Branch pipe for connecting the DHW circuit #3430609
      Value: 1/2"
    27. Create: Dimensions WxHxD #3430610
      Value: 640x830x410 mm
    28. Create: Weight #3430611
      Value: 80 kg
    29. Create: Additional Information #3430612
      Value: EUROSIT gas automation
    30. Create: Image #6328597
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7546096177826223165/orig
    31. Create: Image #6328598
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id8567532526048697105/orig
    32. Create: Image #6328599
      URL: https://avatars.mds.yandex.net/get-mpic/466729/img_id4711331969635628119/orig
    33. Create: Preview image #6328600
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7546096177826223165/orig
  2. Donny Darko 30 April 2023 08:32:43
    Name: Gas TAGANROG GAS APPLIANCE KSGV-16P 16 kW double-circuit; Catalog: Heating boilers