Change history for item: Gas TAGANROG GAS APPLIANCE KSGV-50 50 kW double-circuit

  1. Donny Darko 08 July 2023 08:01:35
    1. Create: Description #3430451
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3430452
      Value: Gas, convection
    3. Create: Burner #3430453
      Value: Gas
    4. Create: Number of circuits #3430454
      Value: Double-circuit
    5. Create: Max. thermal power #3430455
      Value: 50 kW
    6. Create: Min. thermal load #3430456
      Value: 59.50 kW
    7. Create: The combustion chamber #3430457
      Value: Open
    8. Create: Heated area #3430458
      Value: 500 sq.m
    9. Create: Efficiency #3430459
      Value: 92 %
    10. Create: Installation #3430460
      Value: Floor
    11. Create: Primary heat exchanger material #3430461
      Value: Steel
    12. Create: Peculiarities #3430462
      Value: Thermometer
    13. Create: Fuel #3430463
      Value: Natural gas
    14. Create: Natural gas consumption #3430464
      Value: 5 cu. m/hour
    15. Create: Nominal pressure of natural gas #3430465
      Value: 6 - 12.74 mbar
    16. Create: Max. coolant temperature #3430466
      Value: 90 °С
    17. Create: Max. water pressure in the DHW circuit #3430467
      Value: 6 bar
    18. Create: Max. water pressure in the heating circuit #3430468
      Value: 1 bar
    19. Create: Gas connection #3430469
      Value: 3/4"
    20. Create: Heating circuit connection #3430470
      Value: 2"
    21. Create: Branch pipe for connecting the DHW circuit #3430471
      Value: 1/2"
    22. Create: Chimney diameter #3430472
      Value: 180 mm
    23. Create: Dimensions WxHxD #3430473
      Value: 600x1180x800 mm
    24. Create: Weight #3430474
      Value: 180 kg
    25. Create: Additional Information #3430475
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    26. Create: Image #6328575
      URL: https://avatars.mds.yandex.net/get-mpic/1912105/img_id1967474257243787818/orig
    27. Create: Image #6328576
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id959743105338484697/orig
    28. Create: Image #6328577
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id6304718412170414145/orig
    29. Create: Image #6328578
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id1453935344789323/orig
    30. Create: Image #6328579
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id7335275207806030001/orig
    31. Create: Preview image #6328580
      URL: https://avatars.mds.yandex.net/get-mpic/1912105/img_id1967474257243787818/orig
  2. Donny Darko 30 April 2023 08:32:41
    Name: Gas TAGANROG GAS APPLIANCE KSGV-50 50 kW double-circuit; Catalog: Heating boilers