Change history for item: Gas TAGANROG GAS APPLIANCE KSGV-40 40 kW double-circuit

  1. Donny Darko 08 July 2023 08:01:25
    1. Create: Description #3430380
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3430381
      Value: Gas, convection
    3. Create: Burner #3430382
      Value: Gas
    4. Create: Number of circuits #3430383
      Value: Double-circuit
    5. Create: Max. thermal power #3430384
      Value: 40 kW
    6. Create: Min. thermal load #3430385
      Value: 47.60 kW
    7. Create: The combustion chamber #3430386
      Value: Open
    8. Create: Heated area #3430387
      Value: 400 sq.m
    9. Create: Efficiency #3430388
      Value: 92 %
    10. Create: Installation #3430389
      Value: Floor
    11. Create: Primary heat exchanger material #3430390
      Value: Steel
    12. Create: Peculiarities #3430391
      Value: Thermometer
    13. Create: Fuel #3430392
      Value: Natural gas
    14. Create: Natural gas consumption #3430393
      Value: 4 cu. m/hour
    15. Create: Nominal pressure of natural gas #3430394
      Value: 6 - 12.74 mbar
    16. Create: Max. coolant temperature #3430395
      Value: 90 °С
    17. Create: Max. water pressure in the DHW circuit #3430396
      Value: 6 bar
    18. Create: Max. water pressure in the heating circuit #3430397
      Value: 1 bar
    19. Create: Gas connection #3430398
      Value: 3/4"
    20. Create: Heating circuit connection #3430399
      Value: 2"
    21. Create: Branch pipe for connecting the DHW circuit #3430400
      Value: 1/2"
    22. Create: Chimney diameter #3430401
      Value: 180 mm
    23. Create: Dimensions WxHxD #3430402
      Value: 600x1180x800 mm
    24. Create: Weight #3430403
      Value: 170 kg
    25. Create: Additional Information #3430404
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    26. Create: Image #6328557
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7525754609332180417/orig
    27. Create: Image #6328558
      URL: https://avatars.mds.yandex.net/get-mpic/1704682/img_id3713879200838089728/orig
    28. Create: Image #6328559
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id858659953326828065/orig
    29. Create: Image #6328560
      URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id4682623250220215568/orig
    30. Create: Image #6328561
      URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id5923000816699828303/orig
    31. Create: Preview image #6328562
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7525754609332180417/orig
  2. Donny Darko 30 April 2023 08:32:41
    Name: Gas TAGANROG GAS APPLIANCE KSGV-40 40 kW double-circuit; Catalog: Heating boilers