Change history for item: Gas TAGANROG GAS APPLIANCE KSGV-20 20 kW double-circuit

  1. Donny Darko 08 July 2023 08:01:21
    1. Create: Description #3430351
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, principle of operation of gas boiler
    2. Create: Type of heating boiler #3430352
      Value: Gas, convection
    3. Create: Burner #3430353
      Value: Gas
    4. Create: Number of circuits #3430354
      Value: Double-circuit
    5. Create: Max. thermal power #3430355
      Value: 20 kW
    6. Create: Min. thermal load #3430356
      Value: 23.80 kW
    7. Create: The combustion chamber #3430357
      Value: Open
    8. Create: Heated area #3430358
      Value: 200 sq.m
    9. Create: Efficiency #3430359
      Value: 92 %
    10. Create: Installation #3430360
      Value: Floor
    11. Create: Primary heat exchanger material #3430361
      Value: Steel
    12. Create: Peculiarities #3430362
      Value: Thermometer
    13. Create: Fuel #3430363
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3430364
      Value: 1.9 cu. m/hour
    15. Create: LPG consumption #3430365
      Value: 1.42 kg/hour
    16. Create: Nominal pressure of natural gas #3430366
      Value: 6 - 12.74 mbar
    17. Create: Permissible LPG pressure #3430367
      Value: 29.4 mbar
    18. Create: Max. coolant temperature #3430368
      Value: 90 °С
    19. Create: Hot water capacity at t 25°C #3430369
      Value: 9 l/min
    20. Create: Hot water capacity at t 35°C #3430370
      Value: 5 l/min
    21. Create: Max. water pressure in the DHW circuit #3430371
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3430372
      Value: 1 bar
    23. Create: Gas connection #3430373
      Value: 1/2"
    24. Create: Heating circuit connection #3430374
      Value: 2"
    25. Create: Branch pipe for connecting the DHW circuit #3430375
      Value: 1/2"
    26. Create: Chimney diameter #3430376
      Value: 124 mm
    27. Create: Dimensions WxHxD #3430377
      Value: 400x690x510 mm
    28. Create: Weight #3430378
      Value: 50 kg
    29. Create: Additional Information #3430379
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    30. Create: Image #6328551
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id8037751990708450693/orig
    31. Create: Image #6328552
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id4748736424326205470/orig
    32. Create: Image #6328553
      URL: https://avatars.mds.yandex.net/get-mpic/1620389/img_id5840823575579111208/orig
    33. Create: Image #6328554
      URL: https://avatars.mds.yandex.net/get-mpic/1926093/img_id1495858903157429311/orig
    34. Create: Image #6328555
      URL: https://avatars.mds.yandex.net/get-mpic/1525355/img_id3337872590487260400/orig
    35. Create: Preview image #6328556
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id8037751990708450693/orig
  2. Donny Darko 30 April 2023 08:32:40
    Name: Gas TAGANROG GAS APPLIANCE KSGV-20 20 kW double-circuit; Catalog: Heating boilers