Change history for item: Gas TAGANROG GAS APPLIANCE KSG-16 16 kW single-circuit

  1. Donny Darko 08 July 2023 08:01:13
    1. Create: Description #3430301
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: single-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, gas boiler operation principle
    2. Create: Type of heating boiler #3430302
      Value: Gas, convection
    3. Create: Burner #3430303
      Value: Gas
    4. Create: Number of circuits #3430304
      Value: Single-loop
    5. Create: Max. thermal power #3430305
      Value: 16 kW
    6. Create: Min. thermal load #3430306
      Value: 19 kW
    7. Create: The combustion chamber #3430307
      Value: Open
    8. Create: Heated area #3430308
      Value: 160 sq.m
    9. Create: Efficiency #3430309
      Value: 92 %
    10. Create: Installation #3430310
      Value: Floor
    11. Create: Primary heat exchanger material #3430311
      Value: Steel
    12. Create: Peculiarities #3430312
      Value: Thermometer
    13. Create: Fuel #3430313
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3430314
      Value: 1.5 cu. m/hour
    15. Create: LPG consumption #3430315
      Value: 11.2 kg/hour
    16. Create: Nominal pressure of natural gas #3430316
      Value: 6 - 12.74 mbar
    17. Create: Permissible LPG pressure #3430317
      Value: 29.4 mbar
    18. Create: Max. coolant temperature #3430318
      Value: 90 °С
    19. Create: Max. water pressure in the heating circuit #3430319
      Value: 1 bar
    20. Create: Gas connection #3430320
      Value: 1/2"
    21. Create: Heating circuit connection #3430321
      Value: 2"
    22. Create: Chimney diameter #3430322
      Value: 124 mm
    23. Create: Dimensions WxHxD #3430323
      Value: 400x640x510 mm
    24. Create: Weight #3430324
      Value: 50 kg
    25. Create: Additional Information #3430325
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    26. Create: Image #6328539
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3280117975449025459/orig
    27. Create: Image #6328540
      URL: https://avatars.mds.yandex.net/get-mpic/331398/img_id4565308981318576002/orig
    28. Create: Image #6328541
      URL: https://avatars.mds.yandex.net/get-mpic/1614201/img_id2365018495189579410/orig
    29. Create: Image #6328542
      URL: https://avatars.mds.yandex.net/get-mpic/372220/img_id9207719857034898783/orig
    30. Create: Image #6328543
      URL: https://avatars.mds.yandex.net/get-mpic/200316/img_id854054285904545488/orig
    31. Create: Preview image #6328544
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3280117975449025459/orig
  2. Donny Darko 30 April 2023 08:32:40
    Name: Gas TAGANROG GAS APPLIANCE KSG-16 16 kW single-circuit; Catalog: Heating boilers