Change history for item: Gas TAGANROG GAS APPLIANCE KSGV-16 16 kW double-circuit

  1. Donny Darko 08 July 2023 08:01:09
    1. Create: Description #3430272
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, gas boiler operation principle
    2. Create: Type of heating boiler #3430273
      Value: Gas, convection
    3. Create: Burner #3430274
      Value: Gas
    4. Create: Number of circuits #3430275
      Value: Double-circuit
    5. Create: Max. thermal power #3430276
      Value: 16 kW
    6. Create: Min. thermal load #3430277
      Value: 19 kW
    7. Create: The combustion chamber #3430278
      Value: Open
    8. Create: Heated area #3430279
      Value: 160 sq.m
    9. Create: Efficiency #3430280
      Value: 92 %
    10. Create: Installation #3430281
      Value: Floor
    11. Create: Primary heat exchanger material #3430282
      Value: Steel
    12. Create: Peculiarities #3430283
      Value: Thermometer
    13. Create: Fuel #3430284
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3430285
      Value: 1.5 cu. m/hour
    15. Create: LPG consumption #3430286
      Value: 11.2 kg/hour
    16. Create: Nominal pressure of natural gas #3430287
      Value: 6 - 12.74 mbar
    17. Create: Permissible LPG pressure #3430288
      Value: 29.4 mbar
    18. Create: Max. coolant temperature #3430289
      Value: 90 °С
    19. Create: Hot water capacity at t 25°C #3430290
      Value: 7.5 l/min
    20. Create: Hot water capacity at t 35°C #3430291
      Value: 4.5 l/min
    21. Create: Max. water pressure in the DHW circuit #3430292
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3430293
      Value: 1 bar
    23. Create: Gas connection #3430294
      Value: 1/2"
    24. Create: Heating circuit connection #3430295
      Value: 2"
    25. Create: Branch pipe for connecting the DHW circuit #3430296
      Value: 1/2"
    26. Create: Chimney diameter #3430297
      Value: 124 mm
    27. Create: Dimensions WxHxD #3430298
      Value: 400x690x510 mm
    28. Create: Weight #3430299
      Value: 50 kg
    29. Create: Additional Information #3430300
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    30. Create: Image #6328533
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id8458189865020246898/orig
    31. Create: Image #6328534
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id6390579445432554823/orig
    32. Create: Image #6328535
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id3839803053568211870/orig
    33. Create: Image #6328536
      URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id2711686747376192391/orig
    34. Create: Image #6328537
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id9204252369821421175/orig
    35. Create: Preview image #6328538
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id8458189865020246898/orig
  2. Donny Darko 30 April 2023 08:32:39
    Name: Gas TAGANROG GAS APPLIANCE KSGV-16 16 kW double-circuit; Catalog: Heating boilers