Change history for item: Gas boiler Elsotherm T-116 17.14 kW double-circuit

  1. Donny Darko 08 July 2023 08:00:18
    1. Create: Description #3429969
      Value: Type of heating boiler: gas, max. thermal power: 17.14 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, combustion chamber type: closed, power type: single-phase, control: electric
    2. Create: Type of heating boiler #3429970
      Value: Gas, convection
    3. Create: Burner #3429971
      Value: Gas
    4. Create: Number of circuits #3429972
      Value: Double-circuit
    5. Create: Thermal power #3429973
      Value: 7.65 - 17.14 kW
    6. Create: The combustion chamber #3429974
      Value: Closed
    7. Create: Heated area #3429975
      Value: 160 sq.m
    8. Create: Efficiency #3429976
      Value: 93.37 %
    9. Create: Control #3429977
      Value: Electronic
    10. Create: Installation #3429978
      Value: Wall-mounted
    11. Create: Mains voltage #3429979
      Value: Single-phase
    12. Create: Peculiarities #3429980
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3429981
      Value: 5 l
    14. Create: Equipment #3429982
      Value: Display
    15. Create: Fuel #3429983
      Value: Natural gas
    16. Create: Natural gas consumption #3429984
      Value: 1.77 cu. m/hour
    17. Create: Nominal pressure of natural gas #3429985
      Value: 5 - 19.60 mbar
    18. Create: Heat carrier temperature #3429986
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3429987
      Value: 30 - 60 °С
    20. Create: Max. water pressure in the DHW circuit #3429988
      Value: 6 bar
    21. Create: Max. water pressure in the heating circuit #3429989
      Value: 3 bar
    22. Create: Gas connection #3429990
      Value: 3/4"
    23. Create: Heating circuit connection #3429991
      Value: 3/4"
    24. Create: Branch pipe for connecting the DHW circuit #3429992
      Value: 1/2"
    25. Create: Coaxial chimney diameter #3429993
      Value: 60/100 mm
    26. Create: Connection of a separate chimney diameter 80 mm #3429994
      Value: Yes
    27. Create: Dimensions WxHxD #3429995
      Value: 360x705x227mm
    28. Create: Weight #3429996
      Value: 27.5 kg
    29. Create: Image #6328465
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id1989709238845385179.jpeg/orig
    30. Create: Preview image #6328466
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id1989709238845385179.jpeg/orig
  2. Donny Darko 30 April 2023 08:32:35
    Name: Gas boiler Elsotherm T-116 17.14 kW double-circuit; Catalog: Heating boilers