Change history for item: Gas boiler Elsotherm B23Fi 23.3 kW double-circuit

  1. Donny Darko 08 July 2023 08:00:04
    1. Create: Description #3429876
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3429877
      Value: Gas, convection
    3. Create: Burner #3429878
      Value: Gas
    4. Create: Number of circuits #3429879
      Value: Double-circuit
    5. Create: Thermal power #3429880
      Value: 9.30 - 23.30 kW
    6. Create: The combustion chamber #3429881
      Value: Closed
    7. Create: Heated area #3429882
      Value: 230 sq.m
    8. Create: Efficiency #3429883
      Value: 91.8 %
    9. Create: Control #3429884
      Value: Electronic
    10. Create: Installation #3429885
      Value: Wall-mounted
    11. Create: Mains voltage #3429886
      Value: Single-phase
    12. Create: Peculiarities #3429887
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    13. Create: Expansion tank volume #3429888
      Value: 7 l
    14. Create: Equipment #3429889
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3429890
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3429891
      Value: 22.8 cu. m/hour
    17. Create: LPG consumption #3429892
      Value: 1.71 kg/h
    18. Create: Nominal pressure of natural gas #3429893
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3429894
      Value: 30 mbar
    20. Create: Heat carrier temperature #3429895
      Value: 45 - 80 °C
    21. Create: Temperature in the DHW circuit #3429896
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3429897
      Value: 13.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3429898
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3429899
      Value: 2.5 bar
    25. Create: Gas connection #3429900
      Value: 1/2"
    26. Create: Heating circuit connection #3429901
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3429902
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3429903
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3429904
      Value: Yes
    30. Create: Dimensions WxHxD #3429905
      Value: 430x730x210 mm
    31. Create: Weight #3429906
      Value: 239 kg
    32. Create: Image #6328459
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id3196283012938730029.jpeg/orig
    33. Create: Preview image #6328460
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id3196283012938730029.jpeg/orig
  2. Donny Darko 30 April 2023 08:32:34
    Name: Gas boiler Elsotherm B23Fi 23.3 kW double-circuit; Catalog: Heating boilers