Change history for item: Airfel Digifel Premix СP1-40SP 40 kW

  1. Donny Darko 08 July 2023 07:58:58
    1. Create: Description #3429403
      Value: Type of heating boiler: gas, max. thermal power: 40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3429404
      Value: Gas, condensing
    3. Create: Burner #3429405
      Value: Gas
    4. Create: Number of circuits #3429406
      Value: Double-circuit
    5. Create: Thermal power #3429407
      Value: 9.60 - 40 kW
    6. Create: Thermal load #3429408
      Value: 8.90 - 37.70 kW
    7. Create: The combustion chamber #3429409
      Value: Closed
    8. Create: Efficiency #3429410
      Value: 108 %
    9. Create: Control #3429411
      Value: Electronic
    10. Create: Installation #3429412
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3429413
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3429414
      Value: Stainless steel
    13. Create: Mains voltage #3429415
      Value: Single-phase
    14. Create: Peculiarities #3429416
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3429417
      Value: 12 l
    16. Create: Equipment #3429418
      Value: Display
    17. Create: Fuel #3429419
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3429420
      Value: 4.1 cu. m/hour
    19. Create: LPG consumption #3429421
      Value: 2.64 kg/h
    20. Create: Nominal pressure of natural gas #3429422
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3429423
      Value: 37 mbar
    22. Create: Heat carrier temperature #3429424
      Value: 20 - 85 °С
    23. Create: Temperature in the DHW circuit #3429425
      Value: 40 - 65 °С
    24. Create: Hot water capacity at t 30°C #3429426
      Value: 17.1 l/min
    25. Create: Max. water pressure in the DHW circuit #3429427
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3429428
      Value: 3 bar
    27. Create: Gas connection #3429429
      Value: 3/4"
    28. Create: Heating circuit connection #3429430
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3429431
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3429432
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3429433
      Value: Yes
    32. Create: Dimensions WxHxD #3429434
      Value: 460x840x520 mm
    33. Create: Weight #3429435
      Value: 45 kg
    34. Create: Image #6328425
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id1762331218101548325.jpeg/orig
    35. Create: Preview image #6328426
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id1762331218101548325.jpeg/orig
  2. Donny Darko 30 April 2023 08:32:29
    Name: Airfel Digifel Premix СP1-40SP 40 kW; Catalog: Heating boilers