Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 07:58:51
Create:
Description #3429337
Value: Type of heating boiler: gas, max. heating power: 24.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3429338
Value: Gas, condensing
Create:
Burner #3429339
Value: Gas
Create:
Number of circuits #3429340
Value: Double-circuit
Create:
Thermal power #3429341
Value: 5.20 - 24.20 kW
Create:
Thermal load #3429342
Value: 4.80 - 22.40 kW
Create:
The combustion chamber #3429343
Value: Closed
Create:
Efficiency #3429344
Value: 108 %
Create:
Control #3429345
Value: Electronic
Create:
Installation #3429346
Value: Wall-mounted
Create:
Primary heat exchanger material #3429347
Value: Stainless steel
Create:
Secondary heat exchanger material #3429348
Value: Stainless steel
Create:
Mains voltage #3429349
Value: Single-phase
Create:
Peculiarities #3429350
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3429351
Value: 7 l
Create:
Equipment #3429352
Value: Display
Create:
Fuel #3429353
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3429354
Value: 2.37 cu. m/hour
Create:
LPG consumption #3429355
Value: 1.74 kg/hour
Create:
Nominal pressure of natural gas #3429356
Value: 20 mbar
Create:
Permissible LPG pressure #3429357
Value: 37 mbar
Create:
Heat carrier temperature #3429358
Value: 20 - 85 °С
Create:
Temperature in the DHW circuit #3429359
Value: 40 - 65 °С
Create:
Hot water capacity at t 30°C #3429360
Value: 10 l/min
Create:
Max. water pressure in the DHW circuit #3429361
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3429362
Value: 3 bar
Create:
Gas connection #3429363
Value: 3/4"
Create:
Heating circuit connection #3429364
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3429365
Value: 1/2"
Create:
Coaxial chimney diameter #3429366
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3429367
Value: Yes
Create:
Dimensions WxHxD #3429368
Value: 460x840x410 mm
Create:
Weight #3429369
Value: 35 kg
Create:
Image #6328421
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id2540623823342112783.jpeg/orig
Create:
Preview image #6328422
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id2540623823342112783.jpeg/orig
Donny Darko 30 April 2023 08:32:28
Name: Airfel Digifel Premix СP1-25SP 24.2 kW; Catalog: Heating boilers