Change history for item: Gas Roda Krafter BMOD 40 40.5 kW double-circuit

  1. Donny Darko 08 July 2023 06:39:21
    1. Create: Description #3419281
      Value: Type of heating boiler: gas, max. thermal power: 40.50 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3419282
      Value: Gas, convection
    3. Create: Burner #3419283
      Value: Gas
    4. Create: Number of circuits #3419284
      Value: Double-circuit
    5. Create: Thermal power #3419285
      Value: 28.50 - 40.50 kW
    6. Create: The combustion chamber #3419286
      Value: Open
    7. Create: Efficiency #3419287
      Value: 90.8 %
    8. Create: Control #3419288
      Value: Electronic
    9. Create: Installation #3419289
      Value: Floor
    10. Create: Primary heat exchanger material #3419290
      Value: Cast iron
    11. Create: Mains voltage #3419291
      Value: Single-phase
    12. Create: Peculiarities #3419292
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3419293
      Value: 100 l
    14. Create: Equipment #3419294
      Value: Built-in boiler, display
    15. Create: Fuel #3419295
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3419296
      Value: 4.3 cu. m/hour
    17. Create: LPG consumption #3419297
      Value: 3.1 kg/hour
    18. Create: Nominal pressure of natural gas #3419298
      Value: 20 - 25 mbar
    19. Create: Permissible LPG pressure #3419299
      Value: 30 mbar
    20. Create: Heat carrier temperature #3419300
      Value: 45 - 85 °С
    21. Create: Temperature in the DHW circuit #3419301
      Value: 30 - 60 °С
    22. Create: Max. water pressure in the DHW circuit #3419302
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3419303
      Value: 3 bar
    24. Create: Gas connection #3419304
      Value: 3/4"
    25. Create: Heating circuit connection #3419305
      Value: 1"
    26. Create: Branch pipe for connecting the DHW circuit #3419306
      Value: 1/2"
    27. Create: Chimney diameter #3419307
      Value: 150 mm
    28. Create: Dimensions WxHxD #3419308
      Value: 635x1473x635 mm
    29. Create: Weight #3419309
      Value: 201 kg
    30. Create: Image #6323890
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id1145721278350571041/orig
    31. Create: Preview image #6323891
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id1145721278350571041/orig
  2. Donny Darko 30 April 2023 08:28:09