Change history for item: Gas Roda VorTech One CS24

  1. Donny Darko 08 July 2023 06:36:03
    1. Create: Description #3417810
      Value: Type of heating boiler: gas, max. heating power: 24.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3417811
      Value: Gas, convection
    3. Create: Burner #3417812
      Value: Gas
    4. Create: Number of circuits #3417813
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3417814
      Value: 10.10 - 24.60 kW
    6. Create: Thermal load #3417815
      Value: 11.50 - 26.50 kW
    7. Create: The combustion chamber #3417816
      Value: Closed
    8. Create: Efficiency #3417817
      Value: 92.92 %
    9. Create: Control #3417818
      Value: Electronic
    10. Create: Installation #3417819
      Value: Wall-mounted
    11. Create: Mains voltage #3417820
      Value: Single-phase
    12. Create: Peculiarities #3417821
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3417822
      Value: 6 l
    14. Create: Equipment #3417823
      Value: Display
    15. Create: Fuel #3417824
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3417825
      Value: 2.8 cu. m/hour
    17. Create: LPG consumption #3417826
      Value: 2.06 kg/h
    18. Create: Heat carrier temperature #3417827
      Value: 45 - 78 °С
    19. Create: Temperature in the DHW circuit #3417828
      Value: 35 - 57 °С
    20. Create: Hot water capacity at t 25°C #3417829
      Value: 13.7 l/min
    21. Create: Hot water capacity at t 30°C #3417830
      Value: 11.4 l/min
    22. Create: Hot water capacity at t 35°C #3417831
      Value: 9.8 l/min
    23. Create: Hot water capacity at t 40°C #3417832
      Value: 8.6 l/min
    24. Create: Hot water capacity at t 45°C #3417833
      Value: 7.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3417834
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3417835
      Value: 3 bar
    27. Create: Gas connection #3417836
      Value: 3/4"
    28. Create: Heating circuit connection #3417837
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3417838
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3417839
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3417840
      Value: Yes
    32. Create: Dimensions WxHxD #3417841
      Value: 420x700x255mm
    33. Create: Weight #3417842
      Value: 36 kg
    34. Create: Image #6323728
      URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id2495130348713387056.jpeg/orig
    35. Create: Preview image #6323729
      URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id2495130348713387056.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:50
    Name: Gas Roda VorTech One CS24; Catalog: Heating boilers