Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:35:55
Create:
Description #3417744
Value: Type of heating boiler: gas, max. heating power: 22.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3417745
Value: Gas
Create:
Burner #3417746
Value: Gas
Create:
Number of circuits #3417747
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3417748
Value: 10.80 - 22.20 kW
Create:
Max. thermal load #3417749
Value: 24.50 kW
Create:
The combustion chamber #3417750
Value: Open
Create:
Efficiency #3417751
Value: 93 %
Create:
Control #3417752
Value: Electronic
Create:
Installation #3417753
Value: Wall-mounted
Create:
Mains voltage #3417754
Value: Single-phase
Create:
Peculiarities #3417755
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3417756
Value: 6 l
Create:
Fuel #3417757
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3417758
Value: 2.59 cu. m/hour
Create:
LPG consumption #3417759
Value: 1.9 kg/hour
Create:
Nominal pressure of natural gas #3417760
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3417761
Value: 37 mbar
Create:
Max. coolant temperature #3417762
Value: 83 °С
Create:
Max. temperature in the DHW circuit #3417763
Value: 58 °C
Create:
Hot water capacity at t 25°C #3417764
Value: 12.7 l/min
Create:
Hot water capacity at t 30°C #3417765
Value: 10.6 l/min
Create:
Hot water capacity at t 35°C #3417766
Value: 9.1 l/min
Create:
Hot water capacity at t 40°C #3417767
Value: 8 l/min
Create:
Hot water capacity at t 45°C #3417768
Value: 7.1 l/min
Create:
Max. water pressure in the DHW circuit #3417769
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3417770
Value: 3 bar
Create:
Gas connection #3417771
Value: 1/2"
Create:
Heating circuit connection #3417772
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3417773
Value: 1/2"
Create:
Chimney diameter #3417774
Value: 131 mm
Create:
Dimensions WxHxD #3417775
Value: 400x700x250mm
Create:
Weight #3417776
Value: 249 kg
Create:
Image #6323724
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id6063871657546556934/orig
Create:
Preview image #6323725
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id6063871657546556934/orig
Donny Darko 30 April 2023 08:27:49
Name: Gas Roda ECO OS24 22.2 kW double-circuit; Catalog: Heating boilers